–56–
HEAT EXCHANGER
COOL
INSPECTION
1.Measure:
Filler cap opening pressure
Cap opens at pressure below the specified
pressure
Replace.
Cap opening at pressure:
80
100 kPa
(0.8
1.0 kg / cm
2
,
11.44
14.30 psi)
Measurement steps:
Attach the cooling system tester
1
(90890
-01325, YU-24460-01) to the coolant filler cap
2
.
Apply the specified pressure for 10 seconds,
and make sure there is no pressure drop.