134
SPEC
REGLAGE POUR HAUTE ALTITUDE
Température
–30 °C
(–22 °F)
–10 °C
(–14 °F)
10 °C
(50 °F)
Régime de ralenti
(tr/mn)
Altitude
0 ~ 200 m
(0 ~ 700 ft)
MJ
PJ
#150
#50
MJ
PJ
#148
#48
MJ
PJ
#148
#45
1.400
200 ~ 1.500 m
(700 ~ 5.000 ft)
MJ
PJ
#148
#48
MJ
PJ
#148
#45
MJ
PJ
#145
#45
1.400
1.500 ~ 3.000 m
(5.000 ~ 10.000 ft)
MJ
PJ
#148
#45
MJ
PJ
#145
#45
MJ
PJ
#145
#40
1.400
[Caractéristiques du fabricant]
MJ#1, 2, 3: #148
PJ: #45