1. Inspect:
•
Load control relay (with the white coupler)
1
Inspection steps:
•
Disconnect the load control relay from the cou-
pler.
•
Connect the pocket tester (
Ω ×
1) and battery
(12 V) to the load control relay terminals as
shown.
Positive battery terminal
→
Brown
1
Negative battery terminal
→
Brown/White
2
Positive tester probe
→
Red
3
Negative tester probe
→
Blue
4
•
If load control relay does not have continuity
between the red and blue terminals, replace it.
EMERGENCY ENGINE STARTING
(SX600/MM600)
If a short circuit occurred in the lighting system, the
signal system, or the meter system, the engine can
be started in an emergency by cutting off the load
control relay.
1. Disconnect:
•
Load control relay (with the white coupler)
1
2. Start the engine.
SEA8220
Summary of Contents for VX600ERG
Page 1: ...VX600ERG SX600G MM600G VT600G SERVICE MANUAL LIT 12618 02 20 8EA 28197 10 981059 ...
Page 57: ...2 43 INSP ADJ CARBURETORTUNING Guide for carburetion SEA2720 ...
Page 79: ...2 65 INSP ADJ REAR SUSPENSION ...
Page 220: ...8 21 ELEC CHARGING SYSTEM ...
Page 236: ...8 37 ELEC SIGNAL SYSTEM ...
Page 266: ...9 20 SPEC GENERAL TORQUE SPECIFICATIONS DEFINITION OF UNITS ...
Page 267: ...SPEC 9 21 CABLE ROUTING SEA9010 ...
Page 269: ...SPEC 9 23 CABLE ROUTING SEA9010 ...
Page 271: ...SPEC 9 25 CABLE ROUTING SEA9020 ...
Page 273: ...SPEC 9 27 CABLE ROUTING SEA9030 ...
Page 275: ...SPEC 9 29 CABLE ROUTING SEA9030 ...
Page 277: ...SPEC 9 31 CABLE ROUTING SEA9040 ...
Page 279: ...SPEC 9 33 CABLE ROUTING SEA9050 ...
Page 281: ...SPEC 9 35 CABLE ROUTING SEA9050 ...
Page 283: ...SPEC 9 37 CABLE ROUTING SEA9060 ...
Page 287: ...Printed in USA E CR PRINTED ON RECYCLED PAPER ...