6-9
E
JET
PUMP
IMPELLER DUCT AND DRIVE SHAFT
SERVICE POINTS
Drive shaft removal
1. Remove:
●
Impeller
NOTE:
The impeller has left-hand threads. Turn the
impeller clockwise to loosen it.
2. Remove:
●
Nut
1
Drive shaft holder:
YB-06151/90890-06519
Drive shaft holder:
YB-06151/90890-06519
3. Remove:
●
Drive shaft
1
NOTE:
Remove the drive shaft with a press.
4. Remove:
●
Rear bearing
Å
For USA and Canada
ı
For worldwide
Slide hammer set:
YB-06096
Stopper guide plate:
90890-06501
Bearing puller:
90890-06535
Bearing puller claw 1:
90890-06536
Stopper guide stand:
90890-06538
Å
ı