7-31
E
–
+
ELEC
YPVS SERVOMOTOR
CAUTION:
Do not disassemble the YPVS servomotor
unit. It is a sealed unit and if it is faulty it
must be replaced.
YPVS cable adjustment
Refer to “CONTROL SYSTEM” in
chapter 3.
●
Make sure the servomotor operates
properly.
NOTE:
Make sure the pulley operates three sec-
onds after the jumper lead is removed.