5-39
E
POWR
GENERATOR AND STARTER MOTOR
EXPLODED DIAGRAM
REMOVAL AND INSTALLATION CHART
Step
Procedure/Part name
Q’ty
Service points
STATOR COIL AND PICKUP
COIL REMOVAL
Follow the left “Step” for removal.
1
Plastic tie
1
2
Bolt/washer
3/3
NOTE:
These washers hold the pickup coil leads.
Be sure not to pinch the leads between the
projections and the washers when installing
the bolts.
3
Bolt
2
4
Cable holder
1
5
Bolt
6
6
Pickup coil
3
7
Bolt
1
4.9 N • m (0.49 kgf • m, 3.5 ft • Ib)
5
×
14 mm
14 N • m (1.4 kgf • m, 10 ft • Ib)
6
×
35 mm
14 N • m (1.4 kgf • m, 10 ft • Ib)
6
×
14 mm
1
2
2
6
6
5
5
10
9
3
4
7
8
2
5
6
4.9 N • m (0.49 kgf • m, 3.5 ft • Ib)
5
×
14 mm
5
×
14 mm
5
×
14 mm
LT
242
LT
242
LT
242
LT
242
5
×
14 mm
LT
242
Not reusable