264
Chapter 20—Remote Control
DM2000 Version 2—Owner’s Manual
GPI (General Purpose Interface)
The DM2000’s CONTROL port (25-pin D-sub connector) provides
a GPI (General Purpose Interface). You can configure the GPI so that
it will output 8-channel trigger signals when you operate the faders
or User Defined Keys, or receive 2-channel trigger signals to control
DM2000 parameters.
You can assign any function to these trigger signals. In this way, for example, you can con-
trol a “RECORDING” warning light outside a studio from the DM2000, or you can control
the DM2000’s Talkback function or Dimmer function using an outside switch.
See page 350 for more information on pin assignment.
1
Use the DISPLAY ACCESS [SETUP] button to select the GPI Setup page.
2
To assign functions to incoming trigger signals, use the cursor buttons to
select INPUT 1 or 2.
3
Use the Parameter wheel or INC/DEC buttons to select a parameter, then
press [ENTER].
9
1
21
14
9
2
21
15
9
3
21
16
9
4
21
17
22
5
10
6
GPO0
GPO1
GPO2
GPO3
GPO4
GPO5
GPO6
GPO7
GPI0
GPI1
14
15
16
17
18
19
20
21
22
23
24
25
2
3
4
5
6
7
8
9
10
11
12
13
1
This is an example of the external circuit that operates GPI.
In this example, a trigger signal causes the LEDs to light up
when the
button is selected as the trigger signal polarity
in the OUTPUT section. A trigger signal causes the LEDs to
turn off when the
button is selected as the trigger signal
polarity.