Using the Oscillator
279
DM2000 Version 2—Owner’s Manual
Using the Oscillator
The DM2000 features an oscillator that can be used for calibration or diagnostic purposes.
1
Use the DISPLAY ACCESS [UTILITY] button to locate the Oscillator page.
2
Use the cursor buttons to select the parameters, and use the Parameter
wheel, INC/DEC button, or [ENTER] button to set them.
OSCILLATOR ON:
This turns the Oscillator on or off. While the LEVEL parameter is
selected, the [ENTER] button can be used to turn on and off the Oscillator.
LEVEL:
This sets the Oscillator output level, which is displayed by the adjacent meter. This
parameter can be set by using the Parameter wheel regardless of which parameter is cur-
rently selected.
WAVEFORM:
These buttons are used to select the waveforms: SINE 100Hz, SINE 1kHz,
SINE 10kHz, 1kHz/400Hz, PINK NOISE, or BURST NOISE, which is 200 msec pink noise
pulses at four second intervals. If you select 1 kHz/400 Hz, the Oscillator outputs a sine wave
at different frequencies to L, R, and odd/even buses.
ASSIGN:
These buttons are used to assign the Oscillator output to Bus Outs, Aux Sends,
Matrix Sends, and the Stereo Out.
Note: To prevent any sudden tone burst surprises in your monitors or headphones, you may
want to set the LEVEL parameter to minimum before turning on the oscillator.