84
Chapter 7—Input Channels
DM2000 Version 2—Owner’s Manual
7 Input Channels
Patching Input Channels
AD Inputs, Slot Inputs, internal effects processor outputs, Digital or Analog 2TR Inputs,
Bus Outs, or Aux Sends can be patched to the Input Channel Inputs. See “Patching Input
Channels” on page 77 for more information.
Metering Input Channels
Input Channel signal levels can be metered on the Meter pages. See “Metering” on page 127
for more information.
Reversing the Signal Phase
The signal phase of each Input Channel can be reversed as follows.
Using the SELECTED CHANNEL PHASE/INSERT [ ] Button
1
Use the LAYER buttons to select Input Channel Layers, and use the [SEL] but-
tons to select Input Channels.
2
Use the Phase [ ] button to set the phase.
Phase is reversed when the Phase [ ] button indicator is lit.
Phase Pages
Phase settings can be viewed and set on the Phase pages. If the Auto PHASE/INSERT Dis-
play preference is on, these pages appear automatically when you press the Phase [ ] button
in the SELECTED CHANNEL PHASE/INSERT section, turning on the button indicator.
See “Auto PHASE/INSERT Display” on page 274.
1
Use the SELECTED CHANNEL PHASE/INSERT [DISPLAY] button to select the
Phase pages.
The Phase parameters for the 96 Input Channels are divided between two pages. The Input
Channel 1–48 Phase page is shown below. The layout of the other page is the same.
2
Use the cursor buttons or Parameter wheel to select the NOR/REV buttons,
then use the [ENTER] button and INC/DEC buttons to set them.
The NOR/REV buttons can also be selected by using the [SEL] buttons.
GLOBAL NOR/REV:
These buttons allow you to set the phase of all Input Channels
simultaneously.