3 - 131
INSP
ADJ
ELECTRICAL
Charging method using a variable voltage charger
Connect a charger and
ammeter to the battery
and start charging.
Is the amperage higher
than the standard charg-
ing amperage written on
the battery?
NO
YES
Charger
Ammeter
Adjust the voltage to obtain
the standard charging amper-
age.
Set the timer to the charging
time determined by the open-
circuit voltage.
Refer to “BATTERY
INSPECTION AND CHARG-
ING” section.
Adjust the charging voltage to
20 ~ 25 V.
Monitor the amperage for
3 ~ 5 minutes. Is the standard
charging amperage exceeded?
NO
YES
If the amperage does not
exceed the standard charg-
ing amperage after 5 minutes,
replace the battery.
If the required charging time exceeds 5 hours, it is advisable to check
the charging amperage after 5 hours. If there is any change in the
amperage, readjust the voltage to obtain the standard charging amper-
age.
Leave the battery unused for more than 30 minutes before measuring
its open-circuit voltage.
12.8 V
→
Charging is complete.
12.0 ~ 12.7 V
→
Recharging is required.
Under 12.0 V
→
Replace the battery.
Leave the battery unused for
more than 30 minutes before
measuring its open-circuit voltage.
Set the charging voltage to 16-
17 V. (If the charging voltage is
lower, charging will be insuffi-
cient, if it is higher, the battery will
be over-charged.)
NOTE:
NOTE:
Measure the open-circuit
voltage prior to charging.
Summary of Contents for WR250F(W)
Page 51: ...1 26 GEN INFO MEMO...
Page 89: ...1 64 GEN INFO MEMO...
Page 189: ...2 96 SPEC MEMO...
Page 285: ...3 74 INSP ADJ MEMO...
Page 379: ...4 20 TUN MEMO...
Page 831: ...7 10 ELEC MEMO...
Page 847: ...7 26 ELEC MEMO...
Page 869: ...7 48 ELEC MEMO...
Page 877: ...7 56 ELEC MEMO...
Page 893: ...7 72 ELEC MEMO...
Page 903: ...7 82 ELEC MEMO...
Page 910: ......
Page 911: ......