7 - 17
–
+
ELEC
IGNITION SYSTEM
AC MAGNETO INSPECTION
1.
Inspect:
• Pickup coil resistance
Out of specification
→
Replace.
Tester (+) lead
→
Red lead
1
Tester (–) lead
→
White lead
2
Pickup coil
resistance
Tester
selector
position
248 ~ 372
Ω
at
20 °C (68 °F)
Ω
×
100
NEUTRAL SWITCH INSPECTION
1.
Inspect:
• Neutral switch conduct
No continuity while in neutral
→
Replace.
Continuity while in gear
→
Replace.
Tester (+) lead
→
Sky blue lead
1
Tester (–) lead
→
Ground
2
Sb
1
Ground
2
Tester
selector
position
NEUTRAL
Ω
×
1
IN GEAR
EC628000
CDI UNIT INSPECTION
Check all electrical components. If
no fault is found, replace the CDI
unit. Then check the electrical com-
ponents again.
CONTROLE DE L’ALTERNATEUR
AVEC ROTOR A AIMENTATION
PERMANENTE
1.
Contrôler:
• Résistance de la bobine d’excita-
tion
Hors spécifications
→
Remplacer.
Fil (+) du multimètre
→
fil rouge
1
Fil (–) du multimètre
→
fil blanc
2
Résistance de la
bobine
d’excitation
Position du
sélecteur du
multimètre
248 à 372
Ω
à
20 °C (68 °F)
Ω
×
100
CONTROLE DU CONTACTEUR DE
POINT MORT
1.
Contrôler:
• Continuité du contacteur de point
mort
Pas de continuité au point mort
→
Rem-
placer.
Continuité en vitesse
→
Remplacer.
Fil (+) du multimètre
→
fil bleu ciel
1
Fil (–) du multimètre
→
terre
2
Sb
1
Terre
2
Position du
sélecteur
du multi-
mètre
POINT
MORT
Ω
×
1
EN
VITESSE
CONTROLE DU BOITIER C.D.I.
Vérifier tous les composants électriques.
Si aucun défaut n’est trouvé, remplacer
le boîtier CDI, puis vérifier à nouveau
les composants électriques.
SYSTEME D’ALLUMAGE
Summary of Contents for WR250F(W)
Page 51: ...1 26 GEN INFO MEMO...
Page 89: ...1 64 GEN INFO MEMO...
Page 189: ...2 96 SPEC MEMO...
Page 285: ...3 74 INSP ADJ MEMO...
Page 379: ...4 20 TUN MEMO...
Page 831: ...7 10 ELEC MEMO...
Page 847: ...7 26 ELEC MEMO...
Page 869: ...7 48 ELEC MEMO...
Page 877: ...7 56 ELEC MEMO...
Page 893: ...7 72 ELEC MEMO...
Page 903: ...7 82 ELEC MEMO...
Page 910: ......
Page 911: ......