7-13
CHARGING SYSTEM
CHARGING SYSTEM
INSPECTION STEPS
If the battery is not charged, use the following inspection steps.
*1 marked: Refer to "CHECKING THE FUSE" section in the CHAPTER 3.
*2 marked: Refer to "CHECKING AND CHARGING THE BATTERY" section in the CHAPTER 3.
• Remove the following parts before inspection.
1. Seat
2. Fuel tank
• Use the following special tools in this inspection.
*1 Check fuse.
No good
→
Replace fuse and check wire harness.
OK
↓
*2 Check battery.
No good
→
Recharge or replace.
OK
↓
Check each coupler and wire connection.
No good
→
Repair or replace.
OK
↓
Check charging voltage.
OK
→
Charging system is good.
No good
↓
Check AC magneto. (Charging coil)
No good
→
Replace.
OK
↓
Replace rectifier/regulator.
Pocket tester:
YU-3112-C/90890-03112