ELEC
– 49 –
ELECTRIC STARTING SYSTEM
C0NTINUITY
MOVES
3.Starter motor
●
Connect the battery positive terminal
1
and starter motor lead
2
using a jumper
lead
3
.
●
Check the operation of the starter motor.
*
*
1
M
2
3
R
L
/
W
L
/
B
R
WARNING
●
A wire that is used as a jumper lead must
have the equivalent capacity or more as
that of the battery lead, otherwise the
jumper lead may burn.
●
This check is likely to produce sparks, so
be sure that no flammable gas or fluid is
in the vicinity.
*
4.Starting circuit cut-off relay
●
Remove the starting circuit cut-off relay
from the wire harness.
●
Connect the pocket tester (
Ω
×
1) and the
battery (12 V) to the starting circuit cut-off
relay terminals.
Battery (+) terminal
→
Red/Black terminal
1
Battery (–) terminal
→
Green/Yellow terminal
2
Tester (+) lead
→
Red/Black terminal
1
Tester (–) lead
→
Blue/White terminal
3
G
/
Y
Sb
L
/
W
R
/
B
2
1
3
CONTINUITY
●
Check the starting circuit cut-off relay for
continuity.
*
NO CONTINUITY
Replace the starting circuit cut-off relay.
DOES NOT TURN
Repair or replace the starter motor.