– 59 –
–
+
ELEC
EAS00796
CHECKING THE SIGNALING SYSTEM
1. The horn fails to sound.
YES
NO
YES
NO
YES
NO
1. Horn switch
• Check the horn switch for continuity.
Refer to “CHECKING THE SWITCH”.
(Manual No.: 3GD-AE6)
• Is the horn switch OK?
Replace the handle-
bar switch.
2. Voltage
• Connect the pocket tester (DC 20 V) to the
horn connector as shown.
Positive tester probe
→
pink
1
Negative tester probe
→
ground
• Set the main switch to “ON”.
• Push the horn switch.
• Measure the voltage (DC 12 V) of pink at
the horn terminal.
• Is the voltage within specification?
The wiring circuit
from the main switch
to the horn connector
is faulty and must be
repaired.
3. Horn
• Disconnect the black lead at the horn ter-
minal.
• Connect a jumper lead
1
to the horn ter-
minal and ground.
• Set the main switch to “ON”.
• Push the horn switch.
• Does the horn sound?
The wiring circuit
from the horn termi-
nal to ground is faulty
and must be re-
paired.
Replace the horn.