8-39
8
NOTICE
ECB00931
To charge a VRLA (Valve Regulated Lead Acid)
battery, a special (constant-voltage) battery
charger is required. Using a conventional bat-
tery charger will damage the battery.
To store the battery
●
If the ATV will not be used for more than one
month, remove the battery, fully charge it, and
then place it in a cool, dry place.
●
If the battery will be stored for more than two
months, check it at least once a month and fully
charge it if necessary.
NOTICE
ECB00940
Always keep the battery charged. Storing a dis-
charged battery can cause permanent battery
damage.
To install the battery
TIP
Be sure the battery is fully charged.
1. Place the battery in its compartment.
2. Connect the positive battery lead first, then
connect the negative battery lead by installing
their bolt.NOTICE: When installing the bat-
tery, the main switch must be off, and the
positive lead must be connected before
the negative lead.
[ECB01110]
3. Install the battery holding plate by installing
the bolts, and then hook the band to secure
the owner’s tool kit.
4. Install the seat. (See page 4-12.)
1. Positive battery lead (red)
2. Negative battery lead (black)
2
U1BS62E0.book Page 39 Monday, April 18, 2011 6:43 PM