For Service Engineers
Service Information
SI1906002E-001=YSP10 installation and adjustment procedures
87/120
Check the image taken by the PCB camera on the [Move Axis] screen.
Adjust the head unit position manually or by moving axis and make sure that the light gray portion of the
lighting axis is projected on whole angle of view.
Check for safety in and around the machine so that the head unit can be moved
safely.
Release the Emergency Stop button.
Press the [Move Adjust Pos.] button.
Press the [Execute] button.
Check that the measured values are within acceptable ranges. Fill the values in
the check sheet.
Item
Acceptable range
Result values
+/-2 of target value
Bit (outer)
up to 16128
Bit (inner)
up to 16128
Bit (coax)
up to 16128
Bit (IR outer)
up to 16128
Bit (IR inner)
up to 16128
Acceptable ranges
Displayed after
executing the
adjustment.