For Service Engineers
Service Information
SI1906002E-001=YSP10 installation and adjustment procedures
88/120
Press the [Yes] button in the provided confirmation message box. The measured
data is saved and the lightness adjustment of the PCB camera is complete.
If an optional inspection camera is used, adjust its lightness setting.
If the inspection camera is not used, remove the lightness adjustment tool from the machine and finish.
13.10.4. Adjust the inspection camera’s lightness (optional)
Perform the below steps immediately after the previous procedure “13.10.3 Adjust the PCB camera’s
Select “Inspection Camera”.
Set the [Adjust Item] to “Lightness”.
Select “Lightness” for [Adjust Item]. Then select a lighting conditions adjustment
tool by double-clicking “Tool Kind” field.
For the list of the adjustment tools, see “13.10.1 Check lightness adjustment tools”.
Select “Inspection Camera”.
Select a tool to use.