5-35
5
4. Tighten the locknut to the specified
torque.
NOTICE:
Always tighten the
locknut against the adjusting nut, and
then tighten it to the specified torque.
[ECB00082]
Crossover setting
The crossover setting adjusts the timing when
the shock absorber transitions from the soft
spring to the hard spring.
TIP
It is recommended to adjust the crossover
setting a similar distance whenever the
spring preload is adjusted.
The crossover setting is measured from the
bottom of the spring retainer to the top of
the crossover locknut.
Spring preload setting:
Minimum (soft):
Distance A =
496.6 mm (19.55 in)
Standard:
Distance A =
483.9 mm (19.05 in)
Maximum (hard):
Distance A =
471.2 mm (18.55 in)
1. Distance A
1
Tightening torque:
Locknut:
41 N·m (4.1 kgf·m, 30 lb·ft)
UBAS12E0.book Page 35 Monday, November 29, 2021 10:56 AM