6-5
IGNITION SYSTEM
ELEC
2. Inspect:
9
Source coil 1 resistance
Out of specification
→
Replace.
3. Inspect:
9
Source coil 2 resistance
Out of specification
→
Replace.
EC628000
CDI UNIT INSPECTION
Check all electrical components. If no fault is
found, replace the CDI unit. Then check the
electrical components again.
Tester (+) lead
→
Black/
Red lead
1
Tester (–) lead
→
Black
lead
2
Source coil 1
Tester selector
resistance
position
720~1,080
Ω
at
Ω ×
100
20°C (68°F)
Tester (+) lead
→
Green/
Blue lead
1
Tester (–) lead
→
Green/
White lead
2
Source coil 2
Tester selector
resistance
position
44~66
Ω
at
Ω ×
10
20°C (68°F)
5MW-9-30-6 7/6/00 1:36 PM Page 12