6 - 6
–
+
ELEC
IGNITION SYSTEM
2. Inspect:
●
Charging coil 1 resistance
Out of specification
→
Replace.
3. Inspect:
●
Charging coil 2 resistance
Out of specification
→
Replace.
Tester (+) lead
→
Brown lead
1
Tester (–) lead
→
Green lead
2
Charging coil 1
resistance
Tester selector
position
720 ~ 1,080
Ω
at 20 ˚C (68 ˚F)
Ω
×
100
Tester (+) lead
→
Pink lead
1
Tester (–) lead
→
Black lead
2
Charging coil 2
resistance
Tester selector
position
44 ~ 66
Ω
at
20 ˚C (68 ˚F)
Ω
×
10
NEUTRAL SWITCH INSPECTION
1. Inspect:
●
Neutral switch conduct
No continuous while in neutral
→
Replace.
Continuous while in gear
→
Replace.
EC628000
CDI UNIT INSPECTION
Check all electrical components. If no fault is
found, replace the CDI unit. Then check the
electrical components again.
Tester (+) lead
→
Sky blue lead
1
Tester (–) lead
→
Ground
2
Sb
1
Ground
2
Tester selec-
tor position
NEUTRAL
Ω
×
1
IN GEAR