ELECTRICAL COMPONENTS
8-92
battery charger cannot charge the MF battery.
A variable voltage charger is recommended.
d. Charge the battery until the battery’s charg-
ing voltage is 15 V.
NOTE:
Set the charging time at 20 hours (maximum).
e. Measure the battery open-circuit voltage
after leaving the battery unused for more
than 30 minutes.
▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲▲
6. Install:
• Battery
7. Connect:
• Battery leads
(to the battery terminals)
CAUTION:
ECA13630
First, connect the positive battery lead “1”,
and then the negative battery lead “2”.
8. Check:
• Battery terminals
Dirt
→
Clean with a wire brush.
Loose connection
→
Connect properly.
9. Lubricate:
• Battery terminals
10. Install:
• Rider seat
Refer to "GENERAL CHASSIS" on page 4-
1.
EAS28040
CHECKING THE RELAYS
Check each switch for continuity with the
pocket tester. If the continuity reading is incor-
rect, replace the relay.
1. Disconnect the relay from the wire harness.
2. Connect the pocket tester (
Ω
×
1) and bat-
tery (12 V) to the relay terminal as shown.
Check the relay operation.
Out of specification
→
Replace.
Relay unit (starting circuit cut-off relay)
Relay unit (fuel pump relay)
12.8 V or more --- Charging is complete.
12.7 V or less --- Recharging is required.
Under 12.0 V --- Replace the battery.
Recommended lubricant
Dielectric grease
Pocket tester
90890-03112
Analog pocket tester
YU-03112-C
1. Positive battery terminal
2. Negative battery terminal
3. Positive tester probe
4. Negative tester probe
Relay operation
Continuity/No continuity
(between “3” to “4”)
1. Positive battery terminal
2. Negative battery terminal
3. Positive tester probe
4. Negative tester probe
Result
Continuity/No continuity
1. Positive battery terminal
2. Negative battery terminal
3. Positive tester probe
4. Negative tester probe
Result
Continuity/No continuity
Manuals by Motomatrix / www.motomatrix.co.uk / The Solution For Lost Motorcycle Coded Keys