SAFETY INSTRUCTIONS

Before using the scale, carefully read, understand, and follow the “Safety Instructions” described in this manual.  Observe the 

advice given in the “Operations” section to ensure proper operation.  Keep this operation manual handy for reference. 

1)  DO NOT SHOCK LOAD the scale, Never step on or sit on the scale.  Not only will the scale be damaged, but you may    

also be injured.

2)  DO NOT TWIST platform this will damage the scale.

3)  DO NOT APPLY DIRECT WATER SPRAY to underside of scale!!

4)  Do not operate the scale if there is smoke or a burnt smell coming from the scale.  Remove the batteries or unplug the  

AC adaptor immediately.  After making sure that there is no danger, consult your dealer.

  Never try to repair the scale  

by yourself.

5)  This scale is 

not

 an explosion‑proof model.  Do not use the scale in an atmosphere containing flammable gases or  

 

explosive fumes.  A fire or an explosion can result.

6)  Place the item to be weighed in the center of the platform.  Items placed on the edge of the platform may fall off and  

 

cause injury.

7)  When weighing a heavy, large or unbalanced item, make sure the item is stable on the platform, otherwise, an accident  

may occur.

8)  When carrying or moving the scale, be sure to hold it by the bottom of the base with both hands.  If you hold it by the 

platform, the platform or the platform support may become detached causing the scale to fall.  This will damage the scale.  

The platform is designed for easy removal and clean-up.

9)  Do not insert your finger into the gap or holes in the scale.  You may be injured.

10) The PPC-200(W) uses a liquid crystal display.  If the LCD breaks and the liquid leaks from the LCD, do not touch it with 

your fingers.  The liquid is toxic if ingested.  Be especially careful around small children.

To prevent damage to the scale

1)  Do not push the indicator or keys with sharp objects.  They may break or puncture the switch membrane panel.

2)  Use the specified power supply and choose a suitable environment.  If you do not, the weight readings may be inaccurate 

and the scale may be damaged.

3)  The scale is a sensitive weighing instrument, avoid physical shocks.  If you drop something on the scale, step on the plat-

form, or drop it, the scale may be damaged and lose accuracy.

4)  If the scale becomes dirty, wipe it with a soft cloth.  For stubborn stains, apply a little neutral detergent and then wipe the 

scale with a dry cloth.  Do not use thinner, benzene, hot water, or chemical agents, all of which can cause deformation, dis-

coloration, or deterioration of the scale.

5)  Never remove the case.  The fine adjustment section may be damaged and you may be injured by sharp edges on the 

internal parts.

6)  Do not place the scale upside down on the scale platform.

7)  When the low battery indicator appears, replace all six of the batteries.  When installing the batteries, install them accord-

ing to the polarity markings in the case (+, -).  If the scale will not be used for a long period, remove the batteries.

To keep the scale working efficiently

1)  Place the scale on a flat stable surface that will support the scale and the load.

2)  Do not place the scale in an area exposed to direct sunlight or to wind currents from an air conditioner, otherwise, the 

weights will not be accurate.

3)  Do not place the scale near machines that create vibrations or electromagnetic disturbance, such as microwave ovens, 

portable phones, or large motors.  This will affect the accuracy.

4)  The operating temperature range is from –5°C to +35°C (23°F to 95°F).  Do not subject the scale to sudden temperature 

changes; allow the scale to adjust to the new temperature before use.

5)  If the scale is sealed, do not break the seal.  If you break the seal, the scale will not be considered legal for trade.  In this 

case, contact your dealer.  

6)  Do not disassemble or modify the scale, you will void the warranty.  Modified scales will not be legal for trade.

7)  The PPC-200 is not a washdown scale, it is splash-proof.  Do not use a water sprayer on the PPC-200 and do not use it in 

an extremely humid or dusty environment.

8)  The PPC-220W is a washdown scale, but is not a submersible scale.  Do not place the PPC-200W in water higher than 

the bottom of the housing.  Do not spray water up into the underside of the PPC-200W.

Summary of Contents for Accu-weigh PPC-200

Page 1: ...PORATION 1775 S Murray Blvd Colorado Springs CO 80916 USA Tel 719 591 1500 Fax 719 591 1045 YAMATO TECH CORPORATION 112 19425 Langley By Pass Surrey B C V3S 6K1 Canada Tel 604 533 2338 Fax 604 533 0827 PPC 200W WASHDOWN PPC 200 SPLASH PROOF Version 5 00 ...

Page 2: ...the weight readings may be inaccurate and the scale may be damaged 3 The scale is a sensitive weighing instrument avoid physical shocks If you drop something on the scale step on the plat form or drop it the scale may be damaged and lose accuracy 4 If the scale becomes dirty wipe it with a soft cloth For stubborn stains apply a little neutral detergent and then wipe the scale with a dry cloth Do n...

Page 3: ...le 2 C Turning the Scale On and Off 2 D Checking the Battery Level 2 E Zero the Display 2 F Switching Between LB and KG 2 G Setting the Over Under Indicator 3 H Weighing 4 1 Using the Over Under Indicator 4 2 Gross Weighing 4 3 Net Weighing 5 4 Batching 5 I CAL Indicator 6 IV Entering User Parameter Mode 6 V Optional Analog Meter 8 VI Troubleshooting and Error Messages 10 VII User Parameter 11 ...

Page 4: ...r legal for trade operation 14 Battery Cover Tighten securely to maintain washdown seal 15 Outlet of AC adaptor cable Use of an AC adapter voids washdown seal 16 Levelling Legs Rotate to level the scale Fig 1 Front side of the scale Fig 2 Bottom of the scale 1 Weighing system Strain gauge load cell Platform 9 x 9 230 x 230 mm stainless steel Weight display Single face display Type 7 segment LCD Ch...

Page 5: ... securely into the jack Do not washdown the scale if an AC adaptor is in use or if the washdown plug has been removed from the AC jack III B Leveling the Scale Place the scale on a flat and level surface If the scale is not level the readings may not be accurate You can check whether the scale is level by using the bubble level device positioned on the left front surface of the scale Adjust the fe...

Page 6: ...e indicated as under 6 Press and hold the key and push the key Yellow Cor ners This saves the lower limit and moves to the upper limit 7 Press the key to select the digit you want to change 8 Press the up and down arrows to select the desired value 9 Repeat steps 7 and 8 until all digits are set All values above this setpoint will be indicated as over 10 Press and hold the key and push the key Yel...

Page 7: ...less than the under setpoint the large under arrow will appear 3 If the item weighs from the lower setpoint to the upper setpoint inclusive the accept bullseye will appear 4 If the item weighs more than the upper setpoint the large over arrow will appear 4 III H 2 Gross Weighing 1 Begin with no load on the scale the display reading zero and the center zero and stable indicators lit 2 Place the ite...

Page 8: ...eight of the item s and the container Press the key again to return to the net weight 5 To return to gross weighing mode remove all items from the scale platform and press the key III H 4 Batching 1 Begin with no load on the scale the display reading zero and the center zero and stable indicators lit 2 Place an empty container on the scale platform and press the key The weight of the container wil...

Page 9: ...ameter mode This will also activate the CAL annunciator indicating that the scale is not properly configured for legal for trade operation For more information on setting system parameters and entering Test Mode please see the PPC 200W Technical Manual 1 Turn scale on Press and to enter User Parameter Mode The scale will indicate a keyword fol lowed by it s value 2 To select the desired keyword us...

Page 10: ...anual 7 IV Entering User Parameter Mode 3 To change a parameter value use the keys as follows increase value by one increase value by ten decrease value by one decrease value by ten 4 Press to save changes and press to exit User parameter ...

Page 11: ...st and the indicator will move to the under range 2 Use the and keys to align the indicator with the low end of the under range 3 Press the key The indicator will move to the over range 4 Use the and keys to align the indicator with the high end of the over range 5 Press the key to save the calibration and to return to normal weighing mode V Optional Analog Meter WARNING The PPC 200W is NOT WASHDO...

Page 12: ...until the entire number is set 5 Press the key again to save the displayed under setpoint and to display the current over setpoint 6 Press the key to select the digit you want to change 7 Press the or keys to set the desired value 8 Repeat steps 6 and 7 until the entire number is set 9 Press the key to save the displayed upper setpoint and to return to normal weighing mode This sets the register A...

Page 13: ...played It is usually displayed when the plat form is removed or has something wedged under it 4 Initial error on startup When the initial weight is heavier than the permissible zeroing range and the key is pressed this message will be dis played Remove whatever is on the platform and press the key again When the initial weight is lighter than the permissive zeroing range and the key is pressed thi...

Page 14: ... weight gross weight 1 batch 002 Net weight tare weight gross weight 3 batches 003 Display content 1 batch 004 Serial printer format 1 batch 05 000 Communication speed 000 9600 bps 001 600 bps 002 1200 bps 003 2400 bps 004 4800 bps 005 9600 bps 006 19200 bps 007 38400 bps 06 000 Character length 000 8 bits 001 7 bits 07 002 Parity 000 Non 001 Odd 002 Even 08 001 Stop bit length 000 1 bit 001 2 bit...

Reviews: