19
AZ-SD, AZF-G/BT43
6.1 Solenoid function test
6.2 Reset
Fig. 6-1
Fig. 6-2
lighted
6.3 Fabric sensor function test
Fig. 6-3
lighted
6.
Test mode usage
(1) Turn the power OFF.
(2) While pressing the “▲”
and “▼”
keys, turn
the power ON.
(3) Press the “MODE”
key several times to light
the lamps as below.
“TENSION”
lamp
“END”
lamp
(4) While keeping pressing the “LOCK”
key, each
solenoid functions.
(5) Return to the normal mode by turning the
power OFF.
The tension releaser solenoid
can be tested.
The stitch plate tongue sole-
noid can be tested.
either lamp
lighted
This is to reset the memory to the condition at
shipment.
(1) Turn the power OFF.
(2) While pressing the “▲”
and “▼”
keys, turn
the power ON.
(3) Press the “MODE”
key several times to light
the
“END”
and
“TENSION”
lamps.
(4) Press the
“LOCK”
key and reset the memory.
“ok”
The memory is reset completely.
“EE”
The memory is in abnormal condition.
(not reset)
(5) Turn the power OFF.
If the display shows
“EE”, make contact with the
agency where you buy this equipment.
(1) Turn the power OFF.
(2) While pressing the “▲”
and “▼”
keys, turn
the power ON.
(3) Press the “MODE”
key several times to light
the
“START”
and
“END”
lamps.
“oo”
The fabric sensor is covered.
“- -”
The fabric sensor is not covered.
(4) Turn the power OFF.