9
AZ-SD, AZF-G/BT43
(1) Connect the black wire ① (for GND) and the
white wire ② (for signal) of the intermediate
cable to the tap for automatic motor stop and
presser foot lifter.
black wire ①
white wire ②
Refer to the instruction manual for the motor
used for details.
(2) Connect the solenoid valve cord to the connector
for the presser foot lifter of motor.
2.Installation
2.8.3 Wiring
to
“0V”,
“GND”, or
“circuit
ground”
(The name differs
depending on the manufacturer.)
to “motor stop signal”
and
“presser foot lifter”
Note: Some manufacturers use the same connector for the input and output signals of
presser foot lifter.
Fig. 2-12
(Example) In case of Y motor
Connect the black wire ① and the white wire ② of
the intermediate cable to the pin with the number as
below. (Fig. 2-12)
Option A(white 12P)
black wire ①
white wire ②
Presser foot lifer(blue 3P)
white wire ②
to pin No. 10 for
“0V”
to pin No. 4 for “Up position
stop input”
to pin No. 2 for “Presser
foot input”
2
10
4
②
①
Fig. 2-11
2
10
4
②
①