14
AZ-SD, AZF-G/BT43
3.Proper operation
3.5 Mesh materials
3.6 Automatic motor stop function setting
Fig. 3-9
lighted
If mesh materials are sewn and malfunctions of
the sensor occur, make the following adjustment.
(1) Turn the power OFF.
(2) While pressing the “▲”
and “▼”
keys at the
same time, turn the power ON.
(3) Press the “MODE”
key several times to light
the
“START”
lamp only.
(4) Adjust the value with the “▲”and “▼”
keys
so that the device detects the material end
correctly.
(5) Turn the power OFF.
When sewing normal materials other than mesh materi-
als, return the value to 0.
Fig. 3-10
lighted
By using the automatic motor stop function, the
count from material end detection of the sensor
to motor stop can be set.
(1) Turn the power OFF.
(2) While pressing the “▲”
and “▼”
keys at the
same time, turn the power ON.
(3) Press the “MODE”
key several times to light
the
“START”
and
“TENSION”
lamps.
(4) With the
“▲”and
“▼”
keys, adjust the count
from sewing end to motor stop.
(Two counts indicate one stitch.)
(5) Turn the power OFF.
ÁÔÔÅÎÔÉÏÎ