Digital Platform Scale:

 DP-5602 

Digital Indicator:

 EDI-562 

 

 

 

 

Read this manual and keep it handy. 

 

Yamato Scale Co., Ltd. 

EXPORT-1302 

Summary of Contents for DP-5602

Page 1: ...OPERATION MANUAL Digital Platform Scale DP 5602 Digital Indicator EDI 562 Read this manual and keep it handy Yamato Scale Co Ltd EXPORT 1302 ...

Page 2: ......

Page 3: ...rry out measurement 10 How to power OFF 10 How to Re zero 10 How to carry out tare subtraction 11 1 One touch tare 2 Preset tare How to clear tare subtraction 12 How to enter a code number 12 How to add and total 13 14 1 How to carry out manual addition 2 1 How to carry out automatic addition 2 2 How to return to manual addition How to cancel addition 15 1 How to cancel last addition 2 How to subt...

Page 4: ...e shortage guidance display function enabled How to set the grading function 23 24 Grading function How to set the rank How to clear the rank settings Advanced ranking function 25 Subtractive ranking function How to enable the function How to enter an item name 26 How to register the entries 27 29 1 How to register the entries in block 2 How to register the entries individually The difference betw...

Page 5: ...roperty Caution Denotes a potential risk that may result in injury or damage on the equipment if operated without compliance with this sign Inhibition Denotes what is inhibited Compulsion Denotes what must be followed NOTE Prior to use read carefully the following descriptions of Danger Warning and Caution to understand and comply with them Danger To avoid electrical shock 1 Ground the instrument ...

Page 6: ...trument at temperature between 10C and 40C 5 Work on the level place If not level adjust the leveling legs Storage and Disposition STORING PLACE 1 Do not store the equipment in the place with high temperature humidity or receiving direct sunlight for a long period of time It should also be noted that substantial changes in the ambient temperature may cause condensation inside the equipment resulti...

Page 7: ...r Use this function when you wish to perform weighing or counting of objects along with insufficient excessive judgment These limits can be set using the and keys 18 The key allows the user to edit the registered high and low limits The high and low limits must be set and registered in advance 29 Shortage guidance display Use this function when you wish to produce fixed weight packages These limit...

Page 8: ...ound earth should be added from a screw portion on the platform bottom cover Do not place the instrument in a location exposed to direct sunlight or exposed to direct air blow from air conditioning equipment etc Do not push the display section or the operation key section with a pointed object The instrument must be leveled correctly Adjust its levelness with the leveling leg so that the air bubbl...

Page 9: ...l mount brackets set in the above step 1 hook the brackets onto the 2 wooden tapping screws set in the above step 2 The installation is now complete Caution Since the 4 set screws have been tightened to a fixed torque at the factory the enclosure is water proof and dust proof i e IP66 protection rating easy to wash and hygienically sound HACCP compliance However for the wall mount type indicators ...

Page 10: ...6 Display and operation key sections ...

Page 11: ... printout To set code number To set upper limit To set lower limit To set sample number Determines the setting value entered to Enters a numerical value Clear data entry or tare Change of function on keys to Feed the print paper with key for Printer JPS 508 Changeover between automatic and manual with key To set date with key To set time with key To set item name with key Changeover between weighi...

Page 12: ...e high limit and the low limit being set if a measured value is less than the low limit the red lamp comes on if a measured value is between the lower and high limits the blue lamp comes on or if a measured value is more than the high limit the yellow lamp comes on 2 Auxiliary display Full dot LCD module The auxiliary display can display up to eight items Enter setting values such as the high limi...

Page 13: ...unction enabled High limit in WY or PS mode or Limit 2 with the rank function enabled Tare weight Gross weight and Net weight code number item name 1 date clock time number of times added total the number of times added and the total weight or the total quantity 1 and individual weight value and Net weight code number item name 1 date clock time number of times added and total the number of times ...

Page 14: ... same code appears consult with Yamato Scale s dealer Start measurement Place an object to be weighed on the platform of the instrument The weight of the object appears The following indication shows that the object weighs 10 00 kg If the error code appears after an object is placed on the instrument the weight of the object exceeds the measurable range of the instrument Remove the object from the...

Page 15: ...e weighed in the container The net weight of the object appears 2 Preset tare when tare weight is already known Use the numeric keys and key Example To set the tare weight to 1 50 kg Operating procedure Panel display Remarks Entering the tare weight Enter and in that order A setting value can be entered through the auxiliary display The setting value blinks Press the key The auxiliary display retu...

Page 16: ...number Operating procedure Panel display Remarks Press the key The blinking field is used for setting a value A setting value can be entered through the auxiliary display The setting value blinks Entering the code number Enter and in that order Up to 6 digits can be entered If you enter the wrong number press the key and then enter the correct number Press the key The display returns to normal ind...

Page 17: ...ight of the object appears Addition Press the key with the object placed To cancel the addition press the key There is no change in the indication If the parameter number 035 is set to any numbers other than 0 SEnd appears for the preset seconds If the total value has exceeded the storage capacity of the internal memory after addition the following error codes appear The number of measurement time...

Page 18: ...pears for the preset seconds If the total value has exceeded the storage capacity of the internal memory after addition the following error codes appear The number of measurement times has exceeded The total weight has exceeded Remove the object from the platform The display returns to 0 00 One cycle of automatic addition is now complete By repeating Steps to each measurement value is added to the...

Page 19: ...e key after addition If the parameter number 035 is set to any numbers other than 0 SEnd appears for the preset seconds The last addition weight is canceled regardless of the displayed weight 2 How to subtract weight Operating procedure Panel display Remarks Place weighing items you desire to subtract on platform after addition The display shows the weight of items Press the key The display remain...

Page 20: ...or the total weight The total values appear on the auxiliary display Press the key The display returns to normal indication Continue to carry out the cycle of addition To end the addition and clear the total values To clear the memory of the total values press the key while the total weight or the total number of measurement times is shown The command clears all of the total weight and the total n...

Page 21: ...witches to the PCS display and the PCS lamp comes on Press the key or the key Lo LMT 0 00kg Hi LMT 0 00kg TARE 0 00kg GROSS 0 00kg unitWT 0kg When pressing the key or the key again the display returns to Press the and in that order Lo LMT 0 00kg Hi LMT 0 00kg TARE 0 00kg GROSS 0 00kg unitWT 0 05kg The key substitutes for decimal point Max 5 digits available Press the key The individual weight is s...

Page 22: ...ely Operating procedure Panel display Remarks Press the key The setting value blinks Entering the low limit Enter and in that order The setting value blinks Press the key Press the key The setting value blinks Entering the high limit Enter and in that order The setting value blinks Press the key Weighing start Place an object on the platform of the instrument The under over judgment is performed a...

Page 23: ...meter number 054 The default setting is 2 To change the indication make changes in the user parameter by referring to page 33 Setting Underweight Acceptable weight Overweight 0 Same as the left Same as the left 1 1 1 1 2 Standard 1 1 1 3 1 The unit of bar has been set to 5 scale intervals as default In that case the indications using the and bars can be interpreted into the range of 25 scale inter...

Page 24: ...o make the settings Setting the user parameter No 187 to 1 enables the shortage guidance display function For how to change the user parameter refer to page 33 For setting the high and low limits refer to pages 18 Note When the shortage guidance display function is enabled the PCS mode cannot be used In addition the key is assigned to switch between the WT mode and the shortage guidance display fu...

Page 25: ...the individual weight is too small 1 10 of the scale interval the error code E 001 appears and the individual weight is not set Press the key and reenter an appropriate individual weight Any value less than 1 10 of the scale interval will be discarded from the individual weight entered How to set the work unit Example To change the work unit from pcs standard to each work nuit Operating procedure ...

Page 26: ...set to 5 00 kg 5 10 kg respectively and the individual weight is 0 01 kg Setting Underweight measured weight 4 50kg Acceptable weight measured weight 5 05kg Overweight measured weight 5 50kg 0 Same as the left Same as the left 1 1 1 1 2 Standard 1 1 1 3 1 The unit of bar has been set to 5 scale intervals as default In that case the indications using the and bars can be interpreted into the range o...

Page 27: ...r key Proceeds to LIMIT 2 setting 2 Press the key key Proceeds to LIMIT 3 setting key Returns to LIMIT1 setting key Changes RANK name 3 Enter and in that order key Proceeds to LIMIT 3 setting key Returns to LIMIT1 setting key Changes RANK name Changing a RANK name To change a RANK name press the key Select a rank name from Table 1 and enter the corresponding setting value For example to specify S ...

Page 28: ...platform of the instrument The ranking is performed as soon as weighing starts Depending on the results the LED lamp lights up in the following colors Rank 1 or 8 Blue Rank 2 or 9 Green Rank 3 or 10 Light blue Rank 4 Red Rank 5 Purple Rank 6 Yellow Rank 7 White Table 1 List of rank names Setting value 1 2 3 4 5 6 7 8 9 10 Rank name 1 2 3 4 5 6 7 8 9 10 Setting value 11 12 13 14 15 16 17 18 19 20 R...

Page 29: ...eight 15 kg containing 10 pumpkins that weigh 0 80 to 2 00 kg each One of these pumpkins will be randomly taken out for ranking Rank 1 0 80 to 1 20 kg Rank 2 1 20 to 1 60 kg and Rank 3 1 60 to 2 00 kg Operating procedure Panel display Remarks Place the container on the platform of the instrument The NET lamp comes on Since the automatic tare subtraction is enabled during the subtractive ranking th...

Page 30: ...mode ABC Characters in appear in the lower left of the display Entering the character Input the characters by referring to Table 2 For example to enter G press the key once Press the key The display returns to normal indication The left figure shows an example where the parameter number 072 is set to 5 Table 2 List of characters assigned to each key Key Numeric mode Alphabetic mode T To alphabetic...

Page 31: ...ber 70 Tare weight 1 50 kg Code number 123456 High limit 15 10 kg and Low limit 14 90 kg Operating procedure Panel display Remarks Enter and set all the data in advance Only the preset data can be registered If there are any measured objects on the platform of the instrument after data setting remove them from the platform Press and hold the key The blinking field is used for setting a value This ...

Page 32: ...tion Press and hold the key The blinking field is used for setting a value This key works only when GROSS is zero i e there is nothing on the weighing unit Entering a call number Enter and in that order Press the key The display returns to normal indication Example To register a code number of 123456 in the call number 24 Operating procedure Panel display Remarks For entry of the code number press...

Page 33: ...en GROSS is zero i e there is nothing on the weighing unit The setting value blinks Enter and in that order Enter a call number whose data you wish to display Press the key Call number 70 Tare weight 0 00 kg Code number 000000 High limit 0 00 kg Low limit 0 00 kg Item name Call number 70 Tare weight 3 00 kg Code number 123456 High limit 15 10 kg Low Limit 14 90 kg Item name Grapefruit Call Number ...

Page 34: ...l printer is directly connected to the back of the indicator unit Therefore it requires less space increases its usability and makes a wealth of print contents available A separate model of this printer which can be installed away from the indicator is also available For details refer to the dedicated instruction manual If external relay I O is used The external relay I O enables input of the tare...

Page 35: ...0 enter and in that order After entry press the key The screen returns to the weighing display Time setting Press the key and then the key The example shows 8 20 The ten s place of the hour blinks The time is shown in 24 hour format hour minute Specify the hour in 24 hour format Using the numeric keys enter the hours and minutes in that order Example To change the time to 13 30 enter and in that o...

Page 36: ...etting mode Press the key until the parameter number whose setting you wish to change appears Pressing the key decreases the parameter number The setting value blinks Keep pressing the key automatically cycles through the parameters in the forward direction The key has the same function only goes backward Using the numeric keys change the setting Press the key The setting value blinks If you enter...

Page 37: ...5 TIME AND DATE PRINTED EVERY WEIGHING 011 FEED AFTER PRINT 000 000 NO PAPER FEED 001 020 FEED SPECIFIED LINES AFTER WEIGHING 012 FEED AFTER TOTAL PRINT 000 006 NO PAPER FEED AFTER TOTAL PRINT 001 20 FEED SPECIFIED LINES AFTER TOTAL PRINT 031 NOT USED 000 DO NOT CHANGE 033 TIMING OF LOW LOW LIMIT 000 000 NO SIGNAL SENT For relay output VALID AT 175 27 001 200 LOW LOW LIMIT SIGNAL SENT AT THE TIMIN...

Page 38: ...ZERO DETECTION AUTOMATIC ADDITION BY ZERO DETECTION 070 LCD ASSIGNMENT 000 019 000 3rd LINE LEFT SIDE 071 LCD ASSIGNMENT 000 3rd LINE RIGHT SIDE 072 LCD ASSIGNMENT 000 009 000 4th LINE LEFT SIDE 073 LCD ASSIGNMENT 000 4th LINE RIGHT SIDE 074 PRINTING TIMES 000 001 PRINT ONCE 001 009 PRINT THE SPECIFIED TIMES 086 000 000 CANCEL LAST MINUTE ADDITION DATA 001 SUBTRACT WEIGHT ON PLATFORM FROM SCALE ME...

Page 39: ...ment displays this sign during operation Removing the object returns to the weighing display Use the instrument within its rated operating range Removing the platform of the instrument displays this sign during operation Correctly install the platform The panel shows 0 00 and the instrument is operational When the counting function is set to the individual weight specifying a too small individual ...

Page 40: ...e unit of numeric values are incorrect Check the data transmitted by the connected equipment Press the key to reset the error and then restart communication When the optional RS232C is in use This code appears when the BCC values are not matched Check the results of BCC calculated by the connected equipment Press the key to reset the error and then restart communication When the optional RS232C is...

Page 41: ...call number is 0 although the summary setting for individual call numbers is enabled Press the key and set the call number Then restart weighing When the optional USB flash drive feature is used This code appears when a USB flash drive for writing is not connected Check that a USB flash drive has been inserted Press the key to reset the error and then restart communication When the optional USB fl...

Page 42: ...cycle weight 4 digits Call No 3 digits 6 Indication sign Center zero Indicator lights within 0 1 4 division Stable Indicator lights at stable Automatic Indicator lights in automatic mode Shift Indicator lights when key is pressed Lamp indication Net Red LED lights during tare subtraction Under over Under Red LED lights at underweight judgment Accept Blue LED lights at accept condition Over Yellow ...

Page 43: ... digit Code 6 digit Total cycle 4 digit Date 6 digit Time 4 digit Total print Total weight 9 digit Total number of weighing times 4 digit b RS232C interface Connectable device USB Memory PC etc Output data Date Code Gross weight Net weight Tare Total weight Times of addition Number at counting mode Total number Upper limit Lower Limit Input data Addition command Total command Tare command Zero res...

Page 44: ... 300 600 300 600 1200 1200 1500 2000 A 350 350 500 500 850 1200 B 300 500 750 750 1000 1200 C 80 0 10 112 0 20 148 0 20 236 0 30 236 0 50 246 0 50 D 270 270 400 400 720 1070 E 305 495 660 660 855 1070 F φ38 φ70 φ70 φ75 φ75 φ75 G Pole type 556 0 10 903 0 20 910 0 20 935 0 30 935 0 50 nil H Pole type 370 683 896 895 1145 nil Separate Type Standard Integrated Pole Type ...

Page 45: ...41 Desk top Type Separate Stand Type ...

Page 46: ...42 YAMATO SCALE CO LTD 5 22 Saenba cho Akashi 673 8688 Japan Telephone 81 78 918 6157 Telefax 81 78 918 5562 PRINTED IN JAPAN ...