the power supply cord
and so on.

2.

Do not install in the place where there is any

possibility of inflammable gas leakage around the unit.

3.Do not 

get the unit exposed

to vapor or oil steam.

Cautions

Please call Sales/Service Shop for the Installation.

Do not attempt to install the air conditioner by yourself because improper works
may cause electric shock, fire, water leakage.

Connect the earth
cable.

earthing

WARNING

When abnormality such as burnt-small found,
 immediately stop the operation button and
contact sales shop.

OFF

Use an exclusive 
power source
with a circuit 
breaker

ENFORCEMENT

Connect power supply cord
to the outlet completely

Use the proper voltage

Do not use power supply 
cord in a bundle.

Take care not to damage

the power supply cord.

1.Do not use power supply cord extended

or connected in halfway

STRICT

ENFORCEMENT

STRICT

STRICT

ENFORCEMENT

PROHIBITION

PROHIBITION

PROHIBITION

PROHIBITION

Do not start or stop the

operation by disconnecting

Do not channel the air flow directly
at people, especially at infants or
the aged.

Do not try to repair or 
reconstruct by yourself.

Do not use for the purpose of storage of
food, art work, precise equipment,
breeding, or cultivation.

CAUTION

Take fresh air occasionally especially
when gas appliance is running at the
same time.

PROHIBITION

STRICT

ENFORCEMENT

Do not operate the switch with
wet hand.

PROHIBITION

PROHIBITION

PROHIBITION

PROHIBITION

PROHIBITION

Do not install the unit near a fireplace
or other heating apparatus.

Check good condition of the
installation stand

Do not pour water onto the unit
for cleaning

PROHIBITION

Do not place animals or plants in
the direct path of the air flow

Do not place any objects on or
climb on the unit.

Do not place flower vase or water
containers on the top of the unit.

Do not insert objects into the air

inlet or outlet.

PROHIBITION

PROHIBITION

PROHIBITION

    STRICT
ENFORCEMENT

Check proper
installation of  the
drainage securely

WARNING

9

Summary of Contents for optimum YW09H1/I

Page 1: ...AIR CONDITIONER OPERATION MANUAL YW09H1 I YW12H1 I YW18H1 I YW24H1 I Please read this operation manual before using the air conditioner Keep this operation manual for future reference This appliance is filled with R32 ...

Page 2: ......

Page 3: ...contacts should not be no less than 3mm Such means for disconnection must be incorporated in the Make sure installation is done according to local wiring regulation by professional persons A leakage explosion proof breaker must be installed Make sure ground connection is correct and reliable Read the precautions in this manual carefully before operating the unit This appliance is filled with R32 D...

Page 4: ...9 1 2 8 5 10 Contents PARTS AND FUNCTIONS OPERATION INDOOR UNIT INSTALLATION MAINTENANCE CAUTIONS TROUBLE SHOOTING ...

Page 5: ...iver hole should be within 7m without any obstacle as well When electronic started type fluorescent lamp or change over type fluorescent lamp or wireless telephone is installed in the room the receiver is apt to be disturbed in receiving the signals so the distance to the indoor unit should be shorter Full display or unclear display during operation indicates the batteries have been used up Please...

Page 6: ...controller Pos 1 Pos 2 Pos 3 Pos 4 Pos 5 Display circulated LOW MED HI AUTO Autoswing no Air conditioner is running under displayed fan speed When FAN is set to AUTO the air conditioner automatically adjusts the fan speed according to room temperature 2 SWING Press button changes as follows Pos 4 SWING Press button again vertical flap will stop over present position the swing function will be canc...

Page 7: ... 3 hours temp rises O C by 1 futher The unit will run for further 3 hours then stops Temp is lower than temp setting so that room temperature won t be too high for your sleep Temp setting Unit stop 1 hr Decreases 2O C 1 hr Decreases 2O C 3 hrs 3 hrs Rises 1O C SLEEP SLEEP operation starts operation stops In HEAT mode 3 In SMART mode The unit operaters in corresponding sleep mode adapted to the aut...

Page 8: ...ION CONFIRM CANCEL CONFIRM CANCEL All the products are in conformity with the following European provision RoHS The products are fulfilled with the requirements in the directive 2011 65 EU of the European p arliament and of council on the Restriction of the use of Certain Hazardous Substances in Electrical and Electronic Equipment EU RoHS Directive WEEE In accordance with the directive 2012 19 EU ...

Page 9: ...ed ƽ Place possible to drain easily where piping can be conne cted with the outdoor unit ƽ Place where cold air can be spread in a room entirely ƽ Place nearby a power receptacle with enough space around ƽ Place where the distance of more than lm from televisions radios wireless apparatuses and fluorescent lamps can be left ƽ In the case of fixing the remote controller on a wall place where the in...

Page 10: ...ted to the heat insulation of connecting part specially Fixing the indoor unit body Hang surely the unit body onto the upper notches of the mounting plate Move the body from side to side to verify its secure fixing In order to fix the body onto the mounting plate hold up the body aslant from the underside and then put it down perpendicularly mounting plate Unloading of indoor unit body Fix to side...

Page 11: ... tool for R410A Conventional flare tool Clutch type clutch type Rigid type Wing nut type Imperial type A 0 0 5mm 1 0 1 5mm 1 5 2 0mm rth leakage breaker Lean Damage of flare Partial Too outside Correct Incorrect On Drainage It becomes high midway The gap with the ground is too small There is the bad smell from a ditch It waves The end is imm ersed in water Please install the drain hose so as to be d...

Page 12: ...ndoor unit using vacuum cleaner or flaping them lightly otherwise its performance will be affected the cool and dry conditions For Smart Use of The Air Conditioner Replacement of Air Purifying Filter The white side of the photocatalyst air purifying filter face outside and the black side face the unit The green side of the bacteria killing medium air purifying filter face outside and the white sid...

Page 13: ...ITION PROHIBITION PROHIBITION PROHIBITION Do not start or stop the operation by disconnecting Do not channel the air flow directly at people especially at infants or the aged Do not try to repair or reconstruct by yourself Do not use for the purpose of storage of food art work precise equipment breeding or cultivation CAUTION Take fresh air occasionally especially when gas appliance is running at ...

Page 14: ...tes have Cautions 3 If the fuse of indoor unit on PC board is it with the type of T 3 15A 250V outdoor broken change it with the type of T 25A 250V The refrigerating circuit is leak proof 1 Applicable ambient temperature range Specifications The machine is adaptive in following situation The power plug and connecting cable acquired the local 2 If the power supply cord is damaged it must be replace...

Page 15: ...ONDIȚIONAT TIP SPLIT Vă rugăm să citiți acest manual de utilizare înainte de a utiliza aparatul de aer condiționat Păstrați acest manual pentru referințe ulterioare Acest aparat conține refrigerant R32 YW09H1 I YW12H1 I YW18H1 I YW24H1 I ...

Page 16: ......

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ......

Page 21: ......

Page 22: ...230V ...

Page 23: ......

Page 24: ...B Ø60mm B Ø60mm A 130mm C 110mm YW09H1 I A 120mm C 80mm B Ø60mm B Ø60mm YW12H1 I A 150mm C 120mm B Ø60mm B Ø60mm YW18H1 I B Ø60mm B Ø60mm YW24H1 I A 70mm C 113mm 45mm 35mm 30mm 35mm 35mm 30mm 35mm 45mm ...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ......

Page 29: ......

Page 30: ......

Page 31: ......

Page 32: ...ASTON COM S A Sos Pipera nr 55C Dep 4 Sector 2 020308 Bucuresti 0011516654 此框内由厂家印说明书专用号一维码 厂 于定位 实际印刷时删掉 ...

Reviews: