YCO-1049-02-03

PPC-200W

                Technical Manual

Table of Contents

      Before using the scale, carefully read, understand and follow the “Safety Instructions” described in this manual.  Observe the advice given 

in the “Operations” section to ensure proper operation.  Keep this operation manual handy for reference. 

1)    This scale is 

not

 an explosion-proof model.  Do not use the scale in an atmosphere containing fl ammable gases or explosive fumes.  A 

fi re or an explosion can result.

2)    Do not operate the scale if there is smoke or a burned smell coming from the scale.  Unplug the scale immediately.  After making sure that 

there is no danger, consult your dealer.  Never try to repair the scale by yourself.

3)    Never step on or sit on the scale.  Not only will the scale be damaged, but you may also be injured.
4)    Place the item to be weighed in the center of the platform.  Items placed on the edge of the platform may fall off and cause injury.
5)    When weighing a heavy, large or unbalanced item, make sure the item is stable on the platform, otherwise, an accident may occur.
6)    When carrying or moving the scale, be sure to hold it by the bottom of the base with both hands.  If you hold it by the platform, the plat-

form or the platform support may become detached causing the scale to fall.  This will damage the scale.  The platform is designed for 
easy removal and cleanup.

7)    Do not insert your fi nger into the gaps or holes in the scale.  You may be injured.

SAFETY INSTRUCTIONS

I.      Introduction                                                                      1

II.     Set-up Procedures                                                           1

      A.  User Mode                                                                  1
       B. Test Mode                                                                   2
       C. System Parameter Mode                                            3
       D. Calibration Mode                                                         4
       E. Factory Parameter Mode                                            5

III.    Troubleshooting                                                               6

IV.    Parameter Lists                                                                7

      A.  User Parameters                                                         7
       B. System Parameters                                                    8
       C. Factory Parameters                                                    8
       D. Standard Factory Parameter Settings                       11

V.     Wiring Diagram                                                              14

VI.   Parts List                                                                        15

Summary of Contents for PPC-200W

Page 1: ...YCO 1049 02 03 YAMATO CORPORATION 1775 S Murray Blvd Colorado Springs CO 80916 USA Tel 719 591 1500 Fax 719 591 1045 YAMATO TECH CORPORATION 112 19425 Langley By Pass Surrey B C V3S 6K1 Canada Tel 604...

Page 2: ...ce the item to be weighed in the center of the platform Items placed on the edge of the platform may fall off and cause injury 5 When weighing a heavy large or unbalanced item make sure the item is st...

Page 3: ...only the AC adaptor supplied or an adaptor of the same output characteristics Capacity Increment Accuracy Maximum Tare 4 lb 2 kg 0 002 lb 0 001 kg 0 002 lb 0 001 kg 3 990 lb 1 995 kg 10 lb 4 kg 0 005...

Page 4: ...Turn the scale on and short the two TEST jumpers on the left of the PCB above the LCD 5 Once the scale is in Test Mode the display can be rotated through the following functions by pressing Internal C...

Page 5: ...d and it s standard value Example To select zero tracking time press eight times 4 User parameters are also set in the System Parameter Mode Press to cycle through system keywords 30 through 40 After...

Page 6: ...justment mode and the fraction i e 0 2 1 2 or 2 2 for three point of full scale in kilo grams that should be placed on the platform 3 If the scale is in two point span adjustment mode press to enter t...

Page 7: ...bration Mode II E Factory Parameter Mode 1 Enter Test Mode see section II A for details 2 Enter Calibration Mode see section II C for details 3 Press and to enter Factory Parameter Mode The steps are...

Page 8: ...rm Platform weight too high Platform weight too low Material between the platform and the scale body Weighing assembly in contact with wires or case Load cell connector loose or damaged Power board ma...

Page 9: ...erial interface 001 Speci ed commands acceptable 002 Sends zero detection 003 Sends motion detection 004 Sends continuously 04 000 Communication data 000 Net weight 1 batch 001 Net weight tare weight...

Page 10: ...9 001 Neglectable change count 000 010 Number of counts 40 000 Simple test mode 000 User parameter valid 001 User parameter invalid 002 User parameter and simple test mode valid Key Function Descripti...

Page 11: ...mode 000 0 0 00 001 0 0 0 002 0 0 003 004 Not used 63 Pound increment 000 008 64 Pound conversion coef cient 000 Conversion coef cient 1 00000 001 Conversion coef cient 0 705479 002 Conversion coef ci...

Page 12: ...01 Enabled 80 Internal resolution 000 Do not use 001 255 81 1 timer ms 000 Do not use 001 255 82 3 timer ms 000 Do not use 001 255 91 Mechanical zero 1 000 255 Automatically set at span adjustment 92...

Page 13: ...ent 003 002 003 003 65 Zero point range 019 019 019 019 66 Zero point range on plus side 012 012 012 012 67 Over scale 003 003 003 003 68 Display hold function 000 000 000 000 69 Hold release against...

Page 14: ...t 001 001 002 001 65 Zero point range 019 019 019 019 66 Zero point range on plus side 012 012 012 012 67 Over scale 003 003 003 003 68 Display hold function 000 000 000 000 69 Hold release against in...

Page 15: ...t 001 001 002 001 65 Zero point range 019 019 019 019 66 Zero point range on plus side 012 012 012 012 67 Over scale 003 003 003 003 68 Display hold function 000 000 000 000 69 Hold release against in...

Page 16: ...YCO 1049 02 03 PPC 200W Technical Manual V Wiring Diagram 14 Note The PPC 200W is not washdown with this option Note The PPC 200W is not washdown with this option...

Page 17: ...YCO 1049 02 03 PPC 200W Technical Manual VI Parts List 15...

Page 18: ...1 27 YAM 1249 200027 CPU Board Assembly 1 28 YAM 1249 200028 Platform Cover S S 1 29 YAM 1249 200029 Level Indicator 1 30 YAM 1249 200030 Sealing Screw 1 32 YAM 1249 200032 Upper Housing Assembly Inc...

Reviews: