YCO-1049-02-03
PPC-200W
Technical Manual
I Introduction
The PPC-200W is available in four capacities. It displays units of either kilograms and one of the fol-
low ing three: continuous pounds, continuous ounces, or pounds and ounces. The specifi cations for
each capacity are in the following table.
Additional specifi cations are provided in the operator’s manual. It is important to note that various fac-
tory parameter settings depend upon the mode (continuous pound, continuous ounce, or pound and
ounce) option selected when the scale was purchased. See section IV.D for the standard set tings
for each mode.
The PPC-200W is not washdown with the optional AC adaptor or the analog meter.
Remove the batteries when operating the scale with the AC adaptor. Use only the AC adaptor supplied
or an adaptor of the same output characteristics.
Capacity Increment Accuracy Maximum Tare
4 lb 2 kg 0.002 lb 0.001 kg 0.002 lb 0.001 kg 3.990 lb 1.995 kg
10 lb 4 kg 0.005 lb 0.002 kg 0.005 lb 0.002 kg 9.975 lb 3.990 kg
20 lb 10 kg 0.01 lb 0.005 kg 0.01 lb 0.005 kg 19.95 lb 9.975 kg
40 lb 20 kg 0.02 lb 0.01 kg 0.02 lb 0.01 kg 39.90 lb 19.95 kg
1
II Set-up Procedures
1. Turn scale on. Press
and
to enter User Pa ram e ter
Mode. The scale will indicate a keyword fol lowed by it’s value.
2. To select the desired keyword, use the keys as follows:
- increase keyword by one
+
- decrease keyword by one
Note: Use the User Parameter List in Section VII to locate the
function to be changed and it’s standard value.
Example: To select lb/kg priority at power on press
nine times.
3. To change a parameter value, use the keys as follows:
- increase value by one
+
- increase value by ten
- decrease value by one
II.A User Mode
Keyword Parameter
Value