background image

 

 

 

 

 

 

Product Return Policy  

If you are not satisfied with your purchase and wish to make a return, contact our customer 

service to inquire about a Return of Merchandise Authorization Number (RMA). 

Merchandise returned without an RMA number will not be accepted and will be returned 

to the sender. Return requests must be made within 15 days of the customer’s receipt of 

the merchandise.  

 

All returns must be unused and in unopened original packaging and include all items and 

manuals originally shipped.  

 

The purchaser is responsible for the shipping cost of return shipment. Insurance on the 

return shipment is required. Damage or loss of merchandise during shipping is the 

responsibility of the sender. Returned shipments that arrive damaged will be returned back 

to the sender, and credit will not be rendered.  

 

All returned products, parts and materials are subject to a 25% restocking fee. Shipping 

and handling cost are non-refundable. All retrofitted, customized and special order item 

sales are final and non-returnable.

 

 

In Case of Request for Repair 

If the failure occurs, stop the operation, turn OFF the power switch, and unplug the power 

plug.  Please contact the sales agency that this unit was purchased, or Yamato Scientific's 

sales office. 

 

< Check following items before contact > 

 Model Name of Product 

 Serial Number 

 Purchase Date 

 Issue (as detailed as possible) 

 

 

Responsibility 

Please follow instructions in this document when using this unit.  Yamato Scientific has no 

responsibility for accidents or breakdown of device due to failure to comply.  Never conduct 

what this document forbids as unexpected accidents or breakdown may result. 
 

Yamato Scientific America Inc. 

925 Walsh Ave, Santa Clara, CA 95050 

Tel: 1-800-292-6286 / 408-235-7725 

http://www.yamato-usa.com

 

 

For customer service: 

Email: customerservice@yamato-usa.com 

For technical support: 

Email: technical@yamato-usa.com 

 

 

18 

WARRANTY POLICY CONTINUED 

Summary of Contents for ULF001C

Page 1: ...ltra Low Freezer of Yamato Scientific To use this unit properly read this Instruction Manual thoroughly before using this unit Keep this instruction manual around this unit for referring at any time W...

Page 2: ...REFRIGERATION SPECIFICATIONS 4 MAINTENANCE 5 UNIT OPERATION 6 TEMPERATURE CONTROL 7 ALARM OPERATION 8 ALARM SYSTEM 8 DRY CONTACT RELAY 8 CONTROL PROGRAMMING 9 CONTROL KEYS DISPLAYS 9 CONTROL PROGRAMMI...

Page 3: ...XCLAMATION POINT CAUTION REFER TO ACCOMPANYING DOCUMENTS 1 Move the freezer to an indoor location and plug the freezer into an appropriate outlet with an adequate power supply Consult your maintenance...

Page 4: ...ly present on the mains supply overvoltage category II Pollution degree 1 WARNING THIS FREEZER IS PROVIDED WITH AN INPUT CIRCUIT PROTECTIVE DEVICE WHICH SHALL BE MAINTAINED AND SERVICED BY QUALIFIED P...

Page 5: ...PLUG ULF001C ULF101C ULF201C 115 VOLTS 60 HERTZ 1 PHASE 15 AMP DEDICATED LINE NEMA 5 15 ULF301C ULF401C ULF501C ULF601C ULF801C 115 VOLTS 60 HERTZ 1 PHASE 20 AMP DEDICATED LINE NEMA 5 20 WARNING ONLY...

Page 6: ...16 5 oz R170 30 to 25 psi R508B 155 psi ULF301C 9 1 3 HP DANFOSS R404A 18 oz R170 30 to 25 psi R508B 155 psi ULF401C 12 1 HP TECUMSEH R404A 19 oz R170 30 to 20 psi R508B 130 psi ULF501C 14 1 HP TECUM...

Page 7: ...in the freezer and store it in a back up freezer or elsewhere 2 Unplug the freezer and open the freezer front door lid 3 Use a cloth to protect the control from dripping water 4 Air out the freezer fo...

Page 8: ...ystem cycles off on high pressure control WARNING ALWAYS LEAVE THE REFRIGERATION SWITCH IN ON POSITION AS THIS WILL AUTOMATICALLY ACTIVATE THE AUTOMATIC STARTING SYSTEM CAUTION COVER SCREEN ON BACK OF...

Page 9: ...TURE SETPOINT The temperature set point can be changed by simply pressing the up arrow to raise or the down arrow to lower the temperature set point WARNING CHANGING THE CONTROL PARAMETERS OUTSIDE OF...

Page 10: ...batteries should be changed approximately every three years with lead acid rechargeable 1 2 Ah min model PS 640F1 or equivalent WARNING ALARM SYSTEM SHOULD BE TESTED EVERY 30 DAYS The dry contact rel...

Page 11: ...r 2 seconds and release to silence audible alarm under normal power or on battery power While unit is in an alarm condition the external alarm relay contacts will remain energized until the alarm cond...

Page 12: ...tton is pressed to display the process value Note When operating on battery power the battery status LED labeled BAT on the front panel will be lit To enter the USER parameter mode hold the scroll key...

Page 13: ...ntial 22 12 X AHY 3 1 Alarm Hysteresis 1 8 1 0 X OHY 3 1 Output Hysteresis 3 6 2 0 X RB 1 Alarm Delay in Minutes 30 X DoR 4 Door Alarm X SP 2 Setpoint X IN2 4 N A N A TO EXIT TAP SCROLL KEY REPEATEDLY...

Page 14: ...value to ON PARAMETERS DESCRIPTION F C ON OFF SPL 3 Lower Setpoint SPH 3 Upper Setpoint Al 2 Alarm INV 1 Temperature Scale SHF 1 Calibration X Hold SCROLL KEY for 2 seconds and release SHF should app...

Page 15: ...13 WIRING DIAGRAM...

Page 16: ...14 ALARM WIRING DIAGRAM...

Page 17: ...15 REFRIGERATION FLOW CHART...

Page 18: ...Specify Voltage 231 VOLTAGE REFRIGERATION HIGH STAGE PARTS PART Air Cooled Condenser No 3CZ0602B 254 Drier No C 053 S 256H Capillary Tube HS 17 HS 20 Oil Separator Temprite Series 900 If Applicable 90...

Page 19: ...itions This warranty shall have force and effect only if all items are used with proper circuits voltages and frequencies and the operation thereof is in accordance with instructions furnished by the...

Page 20: ...are subject to a 25 restocking fee Shipping and handling cost are non refundable All retrofitted customized and special order item sales are final and non returnable In Case of Request for Repair If...

Reviews: