background image

A05G048 

3.

The pressure loss cause by pump pulse should below 1.0 Kgf/cm2 ,otherwise the pipe 
start  to  vibrate.  In  this  case,  a  pulse  reducer  can  be  installed  or  reduce  piping 
length/elbow or increase pipe diameter. 

4.

 

Be aware that pressure discrepancy between input output hose should higher than the 
inner pressure loss of this pump otherwise, overfeeding even siphon phenomenon may 
occur.  In  this  case  an  anti-siphon/backpressure  valve(both  are  optional)  should  be 
installed.     

5.

 

Fluid which is easy to gasify or vaporize (Ex. H

2

O

2

, most solvents). Gas in pump head 

cause variation of flow rate.    In this case purge the gas through drain valve. 

6.

 

Output pipe may install following devices to solve some problems  

 
Pulse damper      -To reduce pipe vibration especially pipe is long/thin/plenty of     

elbows 

Pressure gauge    -To monitor output pipe pressure. 
Release valve      -To prevent pipe from rupture cause by exceptional high 

pressure and secure operator against hazard. 

Back-pressure      -To keep constant pressure of output pipe and improve flow 

valve                      rate stability. 

Pipe injector        -To connect hose/pipe to other pipe. 
Anti-siphon          - If pumping destination altitude is lower than source 
Valve                      tank siphon phenomenon occur. In this case an anti-siphon 

valve should be installed. 

9.

 

The pump installation system as below 

1.

 

Level sensor

 

2.

 

Check valve/filter 

3.

 

Pump 

4.

 

Release valve 

5.

 

Pressure gauge 

6.

 

Back pressure valve 

7.

 

Analog controller 

8.

 

Analog sensor 

9.

 

Target chemical tank 

10.

 

Pipe injector 

11.

 

Source chemical tank 

12.

 

Pulse damper 

13.

 

Flow sensor 

14.

 

Digital/analog flowcontroller 

15.

 

Drain valve pipe 

16.

 

Anit-siphon valve

 

17.

 

I

nvertor 

18.

 

Power supply control box 

 

NOTICE

 

Not all of these devices 

 

are installed. In most 

 

case only part of the 

 

components will be installed

 

installed.

 

Summary of Contents for SMP Series

Page 1: ...A05G048 1 ENGLISH2206 SMP SERIES MECHANICAL DRIVEN DIAPHRAGM PUMP SMP 7015 7030 7060 8015 8020 O P E R A T I O N M A N U A L...

Page 2: ...t Must drain the pipe before installation Install pump to a pressured pipe is extremely high dangerous It may cause a serious injure of operator Do not operate the pump in a pressure higher than speci...

Page 3: ...e phase 3 three phase MATERIAL CODE Material Code AC AF BS VS SS Application General Acid Strong Oxidative Acid General Base Thick fluid Solvent 1 Valve Ball Ceramic Ceramic SUS316 SUS316 SUS316 2 Val...

Page 4: ...0mm 1 O O 9 PVC Foot Valve S S S 10 PTFE Injector 8 10mm 1 O O 11 PVC Injector O O O 12 PVC M24 to 1 2 pipe adaptor 2 O O S Standard O Optional Null Not suitable Model H1 For 10mm hose as PP PVC PTFE...

Page 5: ...cure this product to avoid looseness cause by vibration 6 It is necessary to tighten the joints with bare hands when installing Do not use tools to handle the plastic joints to avoid damage 7 After fi...

Page 6: ...nty of elbows Pressure gauge To monitor output pipe pressure Release valve To prevent pipe from rupture cause by exceptional high pressure and secure operator against hazard Back pressure To keep cons...

Page 7: ...then turn the flow regulator knob while the pump is running Do not turn the flow regulator knob when pump is stop Set the indicator between 0 10 clockwise to reduce flow rate the opposite to increase...

Page 8: ...perature and ventilation of the environment No fluid output or output reduce obviously Motor is not running No output Start the motor Fluid viscosity become high Reduce fluid viscosity Blocking of the...

Page 9: ...ical splash on the pump If do wash off immediately Check for abnormal noise temperature higher then 80 leakage regularly Solve them COMMON ABNORMAL SITUATIONS AND SOLUTIONS at p 8 Check and tighten sc...

Page 10: ...A05G048 10 10 WET PARTS EXPLODED VIEWS SMP 7015 30 60...

Page 11: ...A05G048 11...

Page 12: ...A05G048 12 SMP 8015 20...

Page 13: ...A05G048 13 11 SYSTEM EXPLODED VIEWS SMP 7015 30 60 The wet parts exploded view consult P 10...

Page 14: ...A05G048 14 SMP 8015 8020 Other types of head section exploded view consult P 12...

Page 15: ...0 730 605 890 700 1240 1000 5 0 cm 2 150 125 330 275 720 595 830 650 1150 920 10 0 145 120 320 265 2 Pressure Max kg cm2 10 0 8 0 4 5 5 0 4 5 3 Stroke Length mm 0 0 4 0 0 0 4 5 4 Pulse Rate pulse min...

Page 16: ...A05G048 16 Manufacturer Sale...

Reviews: