Yangzhou Shenzhou Wind-driven Generator Co.,Ltd
URL: www.f-n.cn
9. Trouble shooting
(1)
Why the Electrical equipment failure after connecting with the
system?
Please check the remaining power the battery, and the electrical
○
equipment would not work if the power is not enough. If the power is
enough, please check if the connection between battery and inverter is
correct.
(
2
)
Why cannot charge the battery?
To check if the blades rotate, and the gen
○
erator would not work if the
wind speed is so low or so high. If the rotating of blade is Ok, please
disconnect the battery and inverter from the generator, and then check
the output of generator by voltmeter. If the output is OK, please check
the battery follow the instruction to see if the battery damaged. If the
voltmeter is zero, please check if it’s the problem of generator’s cable.
(
3
)
Why the blade do not move or move slowly with normal wind
speed
?
The rotating of blade would be abnormal if the output line is
○
short-circuited. And please check the generator’s cable with
disconnecting the battery and inverter from the generator.
(
4
)
If we could extend the using of electrical equipment by adding the
capacity of battery
?
It would be a waste of battery and do harm to the battery
○
, if add the