background image

Yangzhou Shenzhou Wind-driven Generator Co.,Ltd 

URL: www.f-n.cn 

 

4.4 Assembly generator 

1.  Connect  the  cable  to  the  bottom  of  generator,  and  then  make  the 

cable go through the pole center. 

 

 

For E1KW/E2KW/E3KW: 

                                                     

 

Terminal No.1 and No.2 connect with temperature; 

Terminal No.3, No.4 and No.5 connect with wind generator power cable.

 

 

E5KW: 

Summary of Contents for E Series

Page 1: ...Yangzhou Shenzhou Wind driven Generator Co Ltd USER S MANUAL FOR E series WIND GENERATOR Version no 1 1 ...

Page 2: ...ance And dismantling of WTGS Please make sure the construction for WTGS mechanical and electronic facilities should be done by professionals Color or figuration of pictures might be varied against physical goods It is forbidden to leave the wind turbine generator working under unloaded state such as without connecting with batteries The safety signs involving the manual are as followed Danger Impr...

Page 3: ... Abstract 4 2 Usage 4 3 Parameter 5 4 Installation of wind generator 5 5 Installation of guy cable tower 11 6 Battery configuration 22 7 Wiring diagram 24 8 Maintenance 错 错 错 错 误 误 误 误 未定 未定 未定 未定义书签 义书签 义书签 义书签 9 Trouble shooting 错 错 错 错 误 误 误 误 未定 未定 未定 未定义书签 义书签 义书签 义书签 ...

Page 4: ...t The E series generator could be applied in the system of wind and solar hybrid as the controller of it has a solar connector solar connection is option contact with factory for details 2 USAGE This E series generator could be both applied for home use and factory use which is available for on gird and off grid While on gird by matching on grid inverter and off gird by matching batteries and off ...

Page 5: ...enerator mode permanent magnet generator permanent magnet generator permanent magnet generator permanent magnet generator Control mode PLC intelligent control PLC intelligent control PLC intelligent control PLC intelligent control Protection mode Dump load Dump load Dump load Dump load Hydraulic brake Rotation diameter M 2 7 3 2 3 7 6 2 Generator life time Year 15 15 15 15 4 Installation of wind g...

Page 6: ...rator on soft lands uneven ground or areas where the ground can be easily influenced by the climates At the same time the distance between generator and battery should be also considered as the longer the distance the less the wastage And please use a thicker cable for long distance connection 4 2 Assembly and connection Note Please firstly connect the controller with battery and then the generato...

Page 7: ...Yangzhou Shenzhou Wind driven Generator Co Ltd URL www f n cn Note From R1 to R5 is the connector of dump loader 4 3 Diagram for generator ...

Page 8: ...n 4 4 Assembly generator 1 Connect the cable to the bottom of generator and then make the cable go through the pole center For E1KW E2KW E3KW Terminal No 1 and No 2 connect with temperature Terminal No 3 No 4 and No 5 connect with wind generator power cable E5KW ...

Page 9: ...enerat or lead wire C Tempera ture control Tempera ture control Brake Brake 2 Connect the generator with the pole by screw 3 Blades 1 The flange has been assembled on the motor shaft before delivery 2 Please note the concave part of blades should face the wind and tight the blade with flap by screw Balance is very important and do ...

Page 10: ...before assembling all blades For finding balance please make a same distance for every apex and then tighten the screw as below Note L1 L2 L3 with tolerance 5mm Tighten the screw after finding balance 4 Assemble the nose cone by screw 5 Connect the tail with the generator with screw ...

Page 11: ...n 6 Please connect cable from the tower to the controller Note controller should be firstly connect with battery 5 Installation of guy cable tower 5 1Foundation sizing Please install the generator only under no wind weather To make the foundation in an open area ...

Page 12: ...4 4 6 Center foundation m 0 6 0 6 0 8 0 6 0 6 0 8 0 9 0 9 1 2 Foundatio n Edge foundation m 0 5 0 5 0 7 0 6 0 6 0 7 0 8 0 8 0 9 5 2 For making basement Dig the basement according to the designed size Then put the anchor in the basement Please assemble the plate as below For generator below 2kw there are two pins needed to fit in the edge foundation For above ...

Page 13: ... tooth hole forwards to the front side Placing the concrete after making the basement ready C25 as below Put the edge anchor into the edge basement and please check the distance between the hook of basement and the center including the basic level of basement and then placing concrete Do as below ...

Page 14: ...w it would need two guy cables for installation and the picture of edge basements is as below Notes To keep the balance of the tension between each cable the height of the basement need to be same with the base of the tower Otherwise the unbalance would cause trouble for the tower ...

Page 15: ...cn 5 3 Assemble the tower 2kw and below 2kw Put the tower into the base and insert the pins in to the hole for it with screwing the pin shaft nut As below 3KW to 5KW Connect the two section of subsidiary pole together and insert it into the main tower as below ...

Page 16: ...Wind driven Generator Co Ltd URL www f n cn Connect 4 pieces of steel wire to the end of the subsidiary pole and then connect the steel wire which corresponding to the edge basement with the U shape spend orchid as below ...

Page 17: ...Wind driven Generator Co Ltd URL www f n cn The steel which corresponding to the front basement need to connect with the chain block as below Erect the subsidiary pole and fix the steel wire to the edge basement as below ...

Page 18: ...Yangzhou Shenzhou Wind driven Generator Co Ltd URL www f n cn Aim the pin hole of tower to the basement and insert the pin with smearing grease as below ...

Page 19: ... could twine the tower with the steel wire for a circle before fixing the wire with the fixture There need to be two fixtures for each steel wire and 10 20 cm need to be left in the end of the wire 3 Besides aiming the steel wire for front basement the ends of all other steel wire need to connect with the corresponding basement And you could fix all wires after the installation of the tower as bel...

Page 20: ...ow 5 Generator installation In the manual for generator part 6 You could erect the tower with a winch tractor and crane Please note when using a winch and tractor there need to be a yoke for generator below 2kw including 2kw Pay attention to the tension of each steel wire in the process of erecting in case of any unbalance ...

Page 21: ... radian for the steel wire 9 3KW and above3KW You need to take the subsidiary pole away and release the steel wire after installation 5 4 Lay down the tower For laying down the tower a no wind weather is needed as well as a yoke which is the same when for installing Break the connection to stop the generator which could be checked in the user s manual If using a crane The harness should be tied to...

Page 22: ...nstant temperature and ventilation area By calculating the output of generator you could decide the number of the battery and the connection series and parallel Then please design a cage for placing the battery controller and inverter To avoid electromagnetic interference after connect the battery please smear the end of wire with grease or anti corrosion material The connecting wire between batte...

Page 23: ...d driven Generator Co Ltd URL www f n cn Parallel connecting is to connect the battery anode with anode cathode with cathode as below Please check the notification using instruction and maintenance with BATTERY INSTRUCTION ...

Page 24: ... f n cn 7 Wiring diagram 7 1 OFF GRID Picture as below Please make sure that the output voltage voltage of battery and the input voltage of battery should be same Do not misconnect the end of battery which would burn the generator battery and inverter out ...

Page 25: ...n 7 2 ON GRID Picture as below Every model of E series could be applied for on grid system with the permission of local government and on gird inverter and on grid controller should be purchased by your own part Please turn off the main supply before connection ...

Page 26: ... If you locate any damage caused by storms or weather replace the blades as using damaged or unbalanced blades will compromise the efficiency and lifetime of windmill 2 Replace lubricant 3 Check to see if nuts and bolts have remained tight on mill and tower 4 Check electric power cables for corrosion and damage If you detect any abnormal corrosion replace cables 5 Please repaint the tower if the p...

Page 27: ...ng of blade is Ok please disconnect the battery and inverter from the generator and then check the output of generator by voltmeter If the output is OK please check the battery follow the instruction to see if the battery damaged If the voltmeter is zero please check if it s the problem of generator s cable 3 Why the blade do not move or move slowly with normal wind speed The rotating of blade wou...

Page 28: ... state of lacking power NOTES Please contact with our engineer by e mail or mobile if you can not solve the problem Color may be different from physical products of picture Please give a kind understanding if the manual has been modified without prior notification Two years warranty would be offered from the date of purchasing Non artificial and Force majeure ...

Reviews: