background image

X4

6

2. Fasten the plastic components to the squeegee cast aluminum base plate

3. Align the eyelet of the rear rubber strip with the squeegee plastic assembly to the

protrusion;

4. Use the pressure strip to snap on both ends

5. Tighten the nut.

3.4 Battery Maintenance

The power system of this washing machine is powered by two 12V

maintenance-free lead-acid batteries in series, and the system voltage is 24V.

●When the machine works for a period of time, the battery power drops, and

when the last bar of the power display meter is flashing, it means that the power is

insufficient and needs to be charged in time;

●When maintaining the battery, please wear protective gloves to avoid contact

with the acid substance of the battery;

● Check whether the battery connecting wire is worn and the contact parts are

loose, and replace it if necessary;

●The terminal of the battery should be kept clean and dry, and there should be no

debris and dust covering it, which is extremely unfavorable to the battery, and will

burn the battery in severe cases.

! ! Notice

In order to make the battery have a long service life, it should be charged in

time after the machine is finished, and deep discharge is strictly prohibited.

The correct charging method of the lead-acid battery: first insert the battery,

then plug in the mains; when fully charged, first cut off the mains, and then pull out

the battery plug.

If the machine is not used for a long time, please fully charge the battery,

disconnect the positive pole of the battery, and store it.

Summary of Contents for X4

Page 1: ...X4 FLOOR SCRUBBER Operating instruction...

Page 2: ...ne Maintenance and Disassembly and Replacement of Wearing Parts 4 Chapter 4 Analysis Table of Common Problems of Floor Scrubber 8 Chapter 5 Maintenance 9 Warranty card 11 Warranty Conditions 11 Floor...

Page 3: ...B Sewage pipe Suction pipe Squeegee Travel switch Performance parameters Category Self propelled Ordinary Drive motor power 300w Fresh water tank capacity 55L Recovery tank capacity 65L Battery capaci...

Page 4: ...silk ropes belts high temperature sundries accumulated water flammable or toxic and harmful substances so as to avoid entanglement burning the main brush and side brush and making them unable to work...

Page 5: ...h is in the ON position Before removing or installing batteries first disconnect the negative battery wire and then disconnect the positive battery wire When rewiring be sure to pay attention to the p...

Page 6: ...e flashing disk Forward and backward switch start this button to control the machine to move forward or backward Speed control switch press the tortoise button the machine runs at low speed press the...

Page 7: ...achine Before the normal operation of the machine make sure that the squeegee is installed correctly and the sewage suction pipe is inserted into the suction port 1 Use the handle to lower the squeege...

Page 8: ...loor it is necessary to add a cleaning pad to avoid the abrasion of the epoxy floor by the brush The machine is filled with clean water and attention should be paid to the clean water so as not to blo...

Page 9: ...placement of Wearing Parts 3 1 Periodic Inspection Regular maintenance and inspection Intervals h 4 50 100 200 500 1 Battery level detection 2 Motor carbon brush inspection 3 Whether the main brush is...

Page 10: ...ness platform The specific replacement is to place the cleaning pad at the bottom of the dial and make it fit firmly with the dial Please refer to the installation of the dial on the machine Notice 3...

Page 11: ...ective gloves to avoid contact with the acid substance of the battery Check whether the battery connecting wire is worn and the contact parts are loose and replace it if necessary The terminal of the...

Page 12: ...non slip nut 2 The installation can be completed by plugging the suction motor pair socket with the machine line 3 6 Self propelled drive controller diagnosis and disassembly The first generation sel...

Page 13: ...e is powered off the sewage is drained and the sewage tank is turned over 2 Remove the handle iron plate fixing screws 3 Loosen the positive and negative wiring of the power supply and drive the posit...

Page 14: ...too loud Please contact the service center Suction motor burned out Replace the suction motor Carbon brush wear Please contact the service center Little or no water flow out Clogged water tank drain v...

Page 15: ...vironment front and rear space at least 300mm Maintenance schedule Warranty Warranty is not covered under the following conditions of use Failure to perform maintenance in accordance with the maintena...

Page 16: ...e guaranteed within the warranty 4 During the warranty period users who do not follow the operating instructions or those who dismantle and repair by themselves will not be covered by the warranty if...

Page 17: ...X4 1...

Reviews: