YZ-X2
18
Chapter 5 Maintenance
Machine life and operational safety must be ensured by proper
and routine maintenance of the machine. The routine maintenance
requirements are tabulated below. Under suitable working
conditions, the maintenance interval can be changed, which must
be determined by the professional responsible for the maintenance.
To perform maintenance operations, the machine must be stopped
(remove the start switch key), so please read the safety section of
the manual carefully.
Conditions of Use
●Ambient temperature: -10
℃~
40
℃
c●The relative humidity of the air: 5%
~
70%
●No conductive dust, no explosion hazard environment
● An environment that does not contain gases or vapors that
corrode metals
●Indoor use, ventilated, non-vibration environment, front and rear
space at least 300mm
Maintenance schedule
Maintenance operation
On
handover
Every
10h
Every
50h
Every
100h
Every
200h
Every
500h
Brush Disc Height Adjustment
Check
Whether the brush plate is wired
or entangled
Squeegee Cleaning Complete
Inspection
Tank cover seal inspection
Screw and nut tightening
inspection
Check the wear of the brush disc
Replacement of absorbent strips
Main brush and drive system
motor carbon brush inspection
and replacement