background image

YZ-X5

9

● Park the machine on a flat ground and put down the scrubber;

●Rotate the plastic handle counterclockwise to remove the water retaining strip brush;

● Lift up the scrubbing brush plate, grab the bristles, lift it up slightly, shake it left and

right, and the brush plate can be removed;

When installing the brush plate, make sure that the flange plate is aligned with the

button hole of the brush plate, and the installation can be completed by rotating in any

direction.

Noted: Ride-on brush discs are made of positive and negative buckles, and the

installation can be completed no matter which direction is rotated.

●When the machine is used to clean the epoxy floor, it is necessary to replace the

ordinary brush plate with the needle plate and add a cleaning pad for cleaning, which

can effectively protect the ground from wear and tear. Please refer to the installation

instructions for operation.

3.3 Replacement and installation of the absorbent strip

●Place the machine on a flat ground, turn off the main power switch, and ensure that

the machine is powered off.

●Put down the squeegee through the handle; after rotating the plastic handle in the

opposite direction, take out the squeegee assembly.

●Unscrew the squeegee assembly nut, remove the bottom plate of the squeegee

assembly, and remove the front and rear rubber strips of the squeegee.

●Install the squeegee blade.

Step 1: Align the holes of the front rubber strip

with the protrusions of the plastic assembly of the

squeegee;

Summary of Contents for YZ-X5

Page 1: ...YZ X5 Floor Scrubber operation instructions ...

Page 2: ...YZ X5 Yangzi Make cleaning easier ...

Page 3: ...on 3 Chapter 2 Use of the Machine 4 Chapter 3 Routine Maintenance and Disassembly and Replacement of Wearing Parts 8 Chapter 4 Analysis Table of Common Problems of Floor Scrubber 13 Chapter 5 Maintenance 14 Warranty card 15 Warranty Conditions 15 ...

Page 4: ...ory Double Brush Double Brush Dosing Single Brush Single Brush Dosing Cleaning efficiency 3650 h 3650 h Brush size 13 inch 2 21 inch Squeegee width 1000mm 1000mm Brush speed 230rpm 230rpm Brush motor power 380w 2 550w Suction motor power 500w 500w Drive motor power 500w 500w Fresh water tank capacity 80L 80L Recovery tank capacity 85L 85L Power unit 24V 100Ah 24V 100Ah Operating hours 2 3h 2 3h To...

Page 5: ...o avoid corrosion and damage to the brush plate and water absorbing strip making them unable to work normally Please keep loose clothing hair fingers and other body parts away from the machine s air vents and any moving parts When the machine stops remember to turn off the power Do not use the machine where the inclination exceeds the rated value of the machine Please do not smoke while charging t...

Page 6: ...ure to pay attention to the polarity of the battery as wrong connection will damage electrical components Avoid direct contact between the positive electrode and the negative electrode because it will cause a large current short circuit generate high heat and even cause a fire Warning When the machine is not used for a long time the battery should be fully charged and then disconnected from the ba...

Page 7: ...single dual control panel Suction lift handle Figure Lift the handle to lift the suction lift Brush plate lift handle Figure Lift the handle to lift the brush plate 2 1 2 Charging the battery The charging socket cable requires at least a power cable with a diameter of 4mm Note The charger is placed on a stable platform and pay attention to moisture proof waterproof and drop proof The charging time...

Page 8: ...at the squeegee is installed correctly and the sewage suction pipe is inserted into the suction port The squeegee has been debugged at the factory and can be used after installation Confirm that the water valve switch at the bottom of the right side of the machine is turned on when driving normally Step 1 Put down the squeegee tripod through the handle Step 2 Pass the squeegee fixing screw through...

Page 9: ... of the water suction motor Lift the left lift handle to lift the squeegee head Turn off the main power switch 2 3 Precautions for machine operation Avoid stopping the machine for a long time in the same place and let the brush clean this will leave unnecessary marks on the ground When cleaning the floor is epoxy floor it is necessary to add a cleaning pad to avoid the abrasion of the epoxy floor ...

Page 10: ...ays store the machine in a clean and dry place and disconnect the battery connector Chapter 3 Routine Maintenance and Disassembly and Replacement of Wearing Parts 3 1 Periodic Inspection 3 2 Brush disk replacement and installation Regular maintenance and inspection Intervals h 4 50 100 200 500 1 Battery level detection 2 Motor carbon brush inspection 3 Whether the main brush is wired the silk is e...

Page 11: ...d to clean the epoxy floor it is necessary to replace the ordinary brush plate with the needle plate and add a cleaning pad for cleaning which can effectively protect the ground from wear and tear Please refer to the installation instructions for operation 3 3 Replacement and installation of the absorbent strip Place the machine on a flat ground turn off the main power switch and ensure that the m...

Page 12: ...orable to the battery and will burn the battery in severe cases Step 2 Attach Plastic Assembly to Squeegee Cast Aluminum Base Plate Step 3 Align the holes of the rear rubber strip with the plastic components of the squeegee to the protrusions Step 4 Use both ends of the bead to snap together Step 5 Tighten the Nuts Notice In order to make the battery have a long service life it should be charged i...

Page 13: ...with the screw of the sewage tank and then tighten it with a non slip nut 2 The installation can be completed by plugging the suction motor pair socket with the machine line 3 6 Controller function diagnosis and disassembly X5 controller is CM2010C type fixed inside the machine head it is a high performance permanent magnet brushless motor controller Drive function Full bridge power MOSFET control...

Page 14: ...en the machine is out of power or cannot be moved due to failure push down the handle of the drive motor to release the electromagnetic brake function which can be easily pushed Controller LED flashes Fault description possible reason Flash 1 time low voltage fault Battery voltage is too low Flashes 2 times in a row Motor open circuit fault Motor wiring is open Blink 3 times in a row Overcurrent M...

Page 15: ...brush plate motor and the solenoid valve is fixed to the iron plate by a nylon tie when replacing just cut off the tie and pull out the solenoid valve outlet pipe Note During installation the clean water pipe should be completely in and out of the solenoid valve outlet to prevent loosening Chapter 4 Analysis Table of Common Problems of Floor Scrubber Problem Reasons Approach Machine is inoperable ...

Page 16: ...ured by proper and routine maintenance of the machine The routine maintenance requirements are tabulated below Under suitable working conditions the maintenance interval can be changed which must be determined by the professional responsible for the maintenance To perform maintenance operations the machine must be stopped remove the start switch key so please read the safety section of the manual ...

Page 17: ...ved by the original factory Damage due to weather or force majeure More than 1 year of warranty or more than 1500 hours of use Warranty card Warranty Conditions 1 Within the day when the user purchases this product the motor is guaranteed for one year more than 7 days from the date of purchase no replacement only warranty 2 Before using the equipment you must understand the instructions and safety...

Page 18: ...le and repair by themselves will not be covered by the warranty if repair is required a cost will be charged 5 The buyer can go to the designated point of the seller for maintenance with the invoice or send the machine back to our company for repair return freight and insurance premiums are paid by themselves ...

Reviews: