11
YZ-X7
Machine maintenance
The machine works best as long as daily, weekly and monthly maintenance procedures are indeed observed.
Warning: Risk of electric shock. Disconnect the battery wiring before maintaining the machine.
Daily maintenance
After each use of the
1.
Drain out and clean the sewage tank
2.
Remove and flush the floating filter screen located in the sewage tank
3.
Drain water tank and flush hot water tank not above 60 ° C as required
4.
Remove the cleaning mat / brush for cleaning. If worn, flip or replace the cleaning mat
5.
Wipe the water suction strip strip. The suction pickup assembly is placed in the raised position to
prevent damage to the rubber strip.
6.
Check the wear condition of the suction water strip strip blade edge. If there is any damage,
adjust the tape at both ends.
7.
Wipe the machine with a multi-purpose cleaner and a wet cloth. For safety, do not flush
the machine with high pressure spraying or water pipe when cleaning it to prevent
electronic parts failure.
8.
Check the wear of the skirt and replace if damage or damage.
9.
Charge the battery, in order to extend the battery life and ensure the best efficiency of
the machine, it must be more than 30 minutes for the machine.
Monthly maintenance
Every 80 hours of use
1.
Remove the water box filter from under the machine and clean the screen to
ensure that the tank is emptied before removing the filter.
2.
Clean the top of the battery against electrode corrosion (refer to Battery Maintenance ").
3.
Check whether the battery wiring is loose.
4.
Check and clean the sewage tank cover strip. More if damaged.
5.
Spray silicone dry lubricant on all pivot and rollers and cover with a layer of waterproof
oil to keep the wheels running.
6 Check for loose nuts and bolts on the machine.
7. Check the machine for leakage.
Maintenance maintenance
Check the carbon brush wear of the drive motor (drive model), vacuum motor and brush
motor every 250 hours. When the carbon brush is worn within 10 mm, the carbon brush is
required. Contact the authorized service center for repair.
Warning: Risk of electric shock. Disconnect the battery wiring before repairing the machine.