Tightening Fasteners
Use the correct amount of torque when you tighten
fasteners on the machine. Applying excessive
torque may damage the fastener or component and
not enough torque may cause a leak or component
failure.
STANDARD TORQUE CHART
CAUTION
The tightening torque in the Standard
Torque Chart
(Page 69)
should be
applied only to the bolts with a “7” head.
(JIS strength classification: 7T)
• Apply 60% torque to bolts
that are not listed.
• Apply 80% torque when
tightened to aluminum alloy.
0000023en2VOM
Thread size × Pitch mm
M6×1.0
M8×1.25
M10×1.5
M12×1.75
M14×1.5
M16×1.5
Tightening Torque
in
·
lb
96 ± 9
-
-
-
-
-
ft
·
lb
-
19 ± 2
36 ± 4
65 ± 7
101 ± 7
167 ± 7
N
·
m
10.8 ± 1.0
25.5 ± 2.9
49.0 ± 4.9
88.3 ± 9.8
137.0 ± 9.8
226.0 ± 9.8
kgf
·
m
1.1 ± 0.1
2.6 ± 0.3
5.0 ± 0.5
9.0 ± 1.0
14.0 ± 1.5
23.0 ± 2.0
Summary of Contents for 0A2V000-U0000
Page 1: ...2V series OPERATION MANUAL 2V Operation Manual P N 0A2V000 U0000 INDUSTRIAL ENGINES 2V750 V ...
Page 12: ...YANMAR WARRANTIES xii 2V Operation Manual This Page Intentionally Left Blank ...
Page 16: ...TABLE OF CONTENTS xvi 2V Operation Manual This Page Intentionally Left Blank ...
Page 42: ...PRODUCT OVERVIEW 26 2V Operation Manual This Page Intentionally Left Blank ...
Page 100: ...PERIODIC MAINTENANCE 84 2V Operation Manual This Page Intentionally Left Blank ...
Page 108: ...LONG TERM STORAGE 92 2V Operation Manual This Page Intentionally Left Blank ...
Page 112: ...SPECIFICATIONS 96 2V Operation Manual This Page Intentionally Left Blank ...