![background image](http://html.mh-extra.com/html/yanmar/3tnv-series/3tnv-series_service-manual_905550046.webp)
2. Inspection and Adjustment
(b) Measurement with hydrometer
When using a hydrometer, the measured
specific gravity must be corrected according to
the temperature at the time of measurement.
The specific gravity of battery electrolyte is
defined with 20 as the standard. Since the
specific gravity increases or decreases by
0.0007 when the temperature varies by 1 ,
correct the value according to the equation
below.
(c) Specific gravity and remaining battery charge
Specific
gravity
(20 )
Discharged
quantity
of electricity
(%)
Remaining
charge
(%)
1.28 0 100
1.26 10 90
1.24 20 80
1.23 25 75
(3) Terminals
Clean if corroded or soiled.
(4) Mounting bracket
Repair or replace it if corroded.
Retighten if loosened.
(5) Battery appearance
Replace the battery if cracked or deformed.
Clean with fresh water if contaminated.
31
Summary of Contents for 3TNV Series
Page 1: ...4TNV106 4TNV106T 4TNV94L 4TNV98 4TNV98T 3TNV82A 3TNV84 T 4TNV84 T 3TNV88 4TNV88 ...
Page 31: ...1 General 1 4 Engine External Views 16 ...
Page 32: ...1 General 1 5 Structural Description 17 ...
Page 156: ...9 Starting Motor 9 1 2 Components 141 ...
Page 157: ...9 Starting Motor 9 1 3 Troubleshooting 142 ...
Page 172: ...9 Starting Motor 9 2 3 Troubleshooting 157 ...
Page 175: ...9 Starting Motor 2 Removal of magnetic switch Remove the M6 bolts 10mm 2 160 ...
Page 185: ...9 Starting Motor 3 Brush 1 Check wear of the brush and the brush spring force 170 ...
Page 194: ...10 Alternator 179 10 1 6 Troubleshooting ...
Page 195: ...11 Electric Wiring 180 11 ELECTRIC WIRING 11 1 Electric Wiring Diagram ...
Page 213: ......