PERIODIC MAINTENANCE
5-32
TNV DI Service Manual
Periodic Maintenance Procedures
6. Replace the element with a new one if the
element is damaged, excessively dirty or oily.
7. Clean inside of the air cleaner cover.
8. Install the element into the air cleaner case
(Figure 5-12, (4)).
9. Reinstall the air cleaner cover making sure you
match the arrow (Figure 5-12, (5)) on the cover
with the arrow on the case (Figure 5-12, (6)).
10. Latch the air cleaner cover to the case.
Perform the following maintenance every 500 hours
of operation.
• Replace Air Cleaner Element
• Replace Fuel Filter
• Clean Fuel Filter / Water Separator
Replace Air Cleaner Element
Replace the air cleaner element (Figure 5-12, (2))
every 500 hours even if it is not damaged or dirty.
When replacing the element, clean the inside of the
air cleaner case (Figure 5-12, (4)).
If the air cleaner is equipped with a double element,
only remove and replace the inner element
(Figure 5-13, (1)) if the engine lacks power or the
dust indicator actuates (if equipped). This is in
addition to replacing the outer element.
CAUTION
• When the engine is operated in dusty
conditions, clean the air cleaner
element more frequently.
• NEVER operate the engine with the air
cleaner element(s) removed. This may
allow foreign material to enter the
engine and damage it.
0000026en
Every 500 Hours of Operation
CAUTION
The maximum air intake restriction, in
terms of differential pressure
measurement, must not exceed 0.90 psi
(6.23 kPa; 635 mmAq). Clean or replace
the air cleaner element if the air intake
restriction exceeds the above
mentioned value.
0000046en
TNV_DI_SM_A4.book 32 ページ 2007年12月6日 木曜日 午前9時23分