FAILURE DIAGNOSIS
1-148
TNV DI Service Manual
Method and Procedure of Failure Diagnosis
Spare Analog (Spare accelerator sensor, Atmospheric pressure sensor)
Related DTC
Work flow
*For details of the work, see after-mentioned "<Diagnosis Method, Procedure>."For the operation
of the diagnosis tool, see “Diagnosis tool Operation Manual” separately.
DTC
P0222/4
Failure with Spare Accelerator Sensor (Low Voltage)
P0223/3
Spare Accelerator Sensor Error (High Voltage)
P0224/2
Intermittent Failure with Spare Accelerator Sensor
P2228/4
Failure with Atmospheric Pressure Sensor (Low Voltage)
P2229/3
Failure with Atmospheric Pressure Sensor (High Voltage)
P2230/2
Intermittent Failure with Atmospheric Pressure Sensor
Check the failure
conditions.
Initial diagnosis with the diagnosis tool
Reserved Analog Input 1 (V) “Signal Data (SD)”
• SD ≤ 200 (0.2V)
=
>
Signal wire disconnected?
• 200 (0.2V) < SD < 4600 (4.6V) =
>
Normal
• 4600 (4.6V) ≤ SD
=
>
GND wire disconnected?
019479-00E
A. Check the current
failure display
B. Check the detected
value to estimate the
cause of failure.
Current failure
exists.
[Check items]:
DTC in the failure history indication
TNV_DI_SM_A4-Troubleshooting.book 148 ページ 2007年11月15日 木曜日 午後5時27分