FAILURE DIAGNOSIS
TNV DI Service Manual
1-191
Method and Procedure of Failure Diagnosis
3. Check of harness continuity:
• Remove the contact input switch and E-ECU from the harness.
• Check the harness continuity using a circuit tester.
*This table takes an oil pressure switch as an example.In the case of charge switch (E09), water temperature switch
(E17), air cleaner switch (E05), oil-water separator switch (E06), check the continuity using the same procedure.
Terminal
Continuity
Status
Switch signal wire E14 (*)
[Between E-ECU and switch connector]
Available
OK: normal
Unavailable
NG: harness disconnection
Between E14 (*) and E38/E43/E48
(power supply line)
Unavailable
OK: normal
Available
NG: Harness short-circuited with power
supply
Between E14 (*) and E28/E45/E47(GND
line)/GND
Unavailable
OK: normal
Available
NG: harness short-circuited with GND
NG
• Check if the harness is damaged, or if the wiring is correct.
• Replace the harness.
OK
Check if the movement of the contact input switch is correctly recognized with the
diagnosis tool “Diagnosis Test”.
→
Go to [4. Movement check of the contact input
switch:]