ELECTRIC WIRING
13-6
3TNV88F Service Manual
Electrical Wire Sizes - Voltage Drop
ELECTRICAL WIRE SIZES - VOLTAGE DROP
Total
current
on circuit
in amps
Length of conductor from source of current to device and back to source (in feet)
10
15
20
25
30
40
50
60
70
80
90
100
110
120
130
140
150
160
170
12 Volts
Wire size (AWG)
5
18
16
14
12
12
10
10
10
8
8
8
6
6
6
6
6
6
6
6
10
14
12
10
10
10
8
6
6
6
6
4
4
4
4
2
2
2
2
2
15
12
10
10
8
8
6
6
6
4
4
2
2
2
2
2
1
1
1
1
20
10
10
8
6
6
6
4
4
2
2
2
2
1
1
1
0
0
0
2/0
25
10
8
6
6
6
4
4
2
2
2
1
1
0
0
0
2/0
2/0
2/0
3/0
30
10
8
6
6
4
4
2
2
1
1
0
0
0
2/0
2/0
3/0
3/0
3/0
3/0
40
8
6
6
4
4
2
2
1
0
0
2/0
2/0
3/0
3/0
3/0
4/0
4/0
4/0
4/0
50
6
6
4
4
2
2
1
0
2/0
2/0
3/0
3/0
4/0
4/0
4/0
60
6
4
4
2
2
1
0
2/0
3/0
3/0
4/0
4/0
4/0
70
6
4
2
2
1
0
2/0
3/0
3/0
4/0
4/0
80
6
4
2
2
1
0
3/0
3/0
4/0
4/0
90
4
2
2
1
0
2/0
3/0
4/0
4/0
100
4
2
2
1
0
2/0
3/0
4/0
24 Volts
5
18
18
18
16
16
14
12
12
12
10
10
10
10
10
8
8
8
8
8
10
18
16
14
12
12
10
10
10
8
8
8
6
6
6
6
6
6
6
6
15
16
14
12
12
10
10
8
8
6
6
6
6
6
4
4
4
4
4
2
20
14
12
10
10
10
8
6
6
6
6
4
4
4
4
2
2
2
2
2
25
12
12
10
10
8
6
6
6
4
4
4
4
2
2
2
2
2
2
1
30
12
10
10
8
8
6
6
4
4
4
2
2
2
2
2
1
1
1
1
40
10
10
8
6
6
6
4
4
2
2
2
2
1
1
1
0
0
0
2/0
50
10
8
6
6
6
4
4
2
2
2
1
1
0
0
0
2/0
2/0
2/0
3/0
60
10
8
6
6
4
4
2
2
1
1
0
0
0
2/0
2/0
3/0
3/0
3/0
3/0
70
8
6
6
4
4
2
2
1
1
0
0
2/0
2/0
3/0
3/0
3/0
3/0
4/0
4/0
80
8
6
6
4
4
2
2
1
0
0
2/0
2/0
3/0
3/0
3/0
4/0
4/0
4/0
4/0
90
8
6
4
4
2
2
1
0
0
2/0
2/0
3/0
3/0
4/0
4/0
4/0
4/0
4/0
100
6
6
4
4
2
2
1
0
2/0
2/0
3/0
3/0
4/0
4/0
4/0