5 C
HECKS AFTER START
-
UP
WARNING
Emergency stop : if an abnormal action occurs, turn the key in the ignition switch to the
OFF position. The electrical system is interrupted and the engine stops. Ask your dealer to
check the machine.
IMPORTANT
The hydraulic oil must be at a temperature from 50°C to 80°C. If the temperature is low,
wait until it reaches 20°C before using the equipment. If you need to use a command lever
before the oil reaches this temperature, handle it gently.
Do not accelerate suddenly if the engine is not hot.
After the engine starts, do not use the machine immediately but respect the following procedure :
1. Run the engine on idle and check that the engine oil pressure alarm light is off.
2. Check that the gauges and the screen correspond to the following statuses :
1= Diesel gauge
normal
2= Cooling fluid temperature indicator
normal
3= Time counter
normal
4= Hydraulic oil temperature gauge
off
5= Battery charge warning alert
off
6= Engine oil pressure alert indicator
off
7= Warning light& Alert light
off
3. Pull the throttle lever to the centre point between idle and full throttle. Run the engine about
5 minutes with no load at the intermediate rotational speed.
4. Unlock the locking levers and lift the bucket from the ground.
87
Summary of Contents for SV26
Page 3: ......
Page 5: ......
Page 7: ......
Page 9: ......
Page 17: ......
Page 19: ...2 ...
Page 24: ...3 Warning labels 7 3 1 Location of the warning adhesive labels ...
Page 25: ...3 Warning labels 8 ...
Page 75: ...58 ...
Page 115: ...9 Rubber tracks 98 9 6 Track replacement 6 4 2 Track replacement page 149 ...
Page 145: ...128 ...
Page 175: ...158 ...
Page 179: ...162 ...
Page 181: ...164 ...
Page 187: ...170 ...
Page 200: ...C Notes 183 ...
Page 204: ...MINI EXCAVATOR http www yanmar eu ...
Page 205: ...MINI EXCAVATOR SV26 USER OPERATION AND MAINTENANCE MANUAL ...