2.3.3 Working near electricity lines
DANGER
Working close to overhead electricity lines is very
dangerous and specific precautions must be taken.
• For this manual, you are considered as working near overhead electricity lines once the
equipment or your machine's load can reach the minimum distances indicated in the table
below.
• Follow these procedures to prevent any accident or injury :
– Wear shows with rubber or leather soles.
– Use a signaller to warn the operator when the machine is too close to an electrical line.
– If the machine is to enter into contact with a cable, the operator must not leave his seat.
– Warn all personnel on the ground to stay far enough away from the machine.
• To determine the voltage of the wires on the work site, contact the electricity production
company concerned.
Voltage (V)
Minimum safety distance (m)
Electricity lines
≤ 50000
3
≥ 50000
5
WARNING
This table is provided for information only. Please refer to the regulations in force in
your country.
2.3.4 Working near obstacles
• When moving in a tunnel, under a bridge or when you are working in an area near tall obs-
tacels, drive the machine carefully to avoid knocking the boom, the arm or the accessory
against these obstacles.
Summary of Contents for ViO38-6
Page 3: ......
Page 5: ......
Page 7: ......
Page 9: ......
Page 17: ......
Page 19: ...2 ...
Page 24: ...3 Warning labels 7 3 1 Location of the warning adhesive labels ...
Page 25: ...3 Warning labels 8 ...
Page 75: ...58 ...
Page 143: ...126 ...
Page 145: ...128 ...
Page 173: ...156 ...
Page 177: ...160 ...
Page 179: ...162 ...
Page 185: ...168 ...
Page 196: ...C Notes 179 ...
Page 201: ...MINI EXCAVATOR http www yanmar eu ...
Page 202: ...USER OPERATION AND MAINTENANCE MANUAL MINI EXCAVATOR ViO38 6 ...