background image

en English

OPERATION 

MANUAL

COLOR DISPLAY

YD42

Summary of Contents for YD42

Page 1: ...en English OPERATION MANUAL COLOR DISPLAY YD42 ...

Page 2: ......

Page 3: ...ublication may be reproduced or used in any form by any means graphic electronic or mechanical including photocopying recording taping or information storage and retrieval systems without the written permission of YANMAR CO LTD Please review and comply with the applicable laws and regulations of the international export control regimes at the territory or country where the product and manual are i...

Page 4: ...tem is ready to use Some features may not be activated or available for screenshots in the manual As a result screenshots of menus and dialogs may not match the look of your unit Important text that requires special attention from the reader is emphasized as follows Ú Note Used to draw the reader s attention to a comment or some important information Warning Used when it is necessary to warn perso...

Page 5: ...e data 13 Missing or faulty data 13 Predefined pages 22 Fuel 22 Requirements 22 Calibrate 22 Fuel management 23 Adding fuel 23 Fuel used 25 Alarms 25 System alarms 25 Engine alarms 26 The alarms dialog 29 Trip log 29 Accessing the trip log 29 Trip 1 29 Trip 2 30 Log 31 User settings 31 Accessing the settings dialog 31 Pages 34 Calibration 34 Damping Contents YD42 Operation Manual 5 ...

Page 6: ...s 42 Simulate 42 Restore defaults 42 Engine setup 43 Global reset 43 About 44 Files 44 USB mass storage device 44 Accessing the files dialog 44 Software update 46 Import system settings 46 Export system settings 47 Maintenance 47 Preventive maintenance 47 Cleaning the display unit 48 Dimensional drawings 49 Technical specifications 50 Supported data 50 NMEA 2000 52 J1939 6 Contents YD42 Operation ...

Page 7: ... menu level or to exit a dialog B Arrow keys Press to move up and down in menus and dialogs Press to adjust a value C Enter key Press to select a menu option and to enter the next menu level Press to activate deactivate a menu dialog option D Menu Backlight key Press once to display the page menu Double press to display the settings dialog Press and hold to open the display setup dialog from where...

Page 8: ...eries of dialogs Respond to the dialog prompts to make fundamental settings You can perform further setup and later change settings using the system settings dialogs Menus Not all pages have a page specific menu A but all page menus give access to the Settings dialog Activate the menu by pressing the Menu key from any page To navigate the menu Use the arrow keys To confirm a selection Press the en...

Page 9: ...elected field Selectedfield Fieldineditmode To cancel editing or leave a dialog Press the pages key Press the menu key Display setup The display setup can be adjusted at any time from the Display setup dialog To access the dialog Press and holding the menu key Backlight level Adjusts the backlight level When the dialog is active you can cycle the preset backlight levels by short presses on the men...

Page 10: ...the pages from default black to white Sleep mode In Sleep mode the backlight for the screen and keys are turned off to save power The system continues to run in the background To exit Sleep mode Press the menu key Selecting a page Scrolling through enabled pages To scroll through the enabled data pages Press the pages key 10 Basic operation YD42 Operation Manual ...

Page 11: ...ng a page To display the list of enabled pages Press and hold the pages key If you do not confirm your selection the menu will timeout and the highlighted page will be displayed Basic operation YD42 Operation Manual 11 ...

Page 12: ... Dual engines C Engine oil pressure D Engine coolant temperature E RPM dial Changing page data Some pages allow you to change which data is displayed on the page To change page data 1 Press the menu key and select the change data option 2 If the page has multiple data fields select the field you want to change 3 Select the data to be shown in the field 4 Repeat steps 2 and 3 to change additional f...

Page 13: ...will be no data reading on the display The example shows a page with missing information Predefined pages Motoring Single engine Dual engines Description A RPM dial B Engine oil pressure C Engine coolant temperature Engine digital Single engine Dual engines Pages YD42 Operation Manual 13 ...

Page 14: ... be available when fuel flow data is available and a Navico fuel storage device is connected to the NMEA 2000 network Page menu From the page menu you can access the refuel dialog by pressing the add fuel option For more information refer to Fuel on page 22 Highway Shows navigation information including visualization of the boat s position on the track The cross track error limit A is shown on the...

Page 15: ...depth and a histogram of recorded depth data The shallow water alarm limit A is visualized on the page Page menu From the page menu you can change the history time range Basic speed depth The speed field includes an acceleration bar A Tide Tidal information shown relative to the yacht s bow Pages YD42 Operation Manual 15 ...

Page 16: ...the page menu you can change the history time range Basic wind angle speed Description A Wind angle indicator red for port and green for starboard tack B True wind speed Beaufort scale indicator 16 Pages YD42 Operation Manual ...

Page 17: ...atible AIS system or an NMEA 2000 VHF that can do AIS Automatic Identification System is connected to the network then any targets detected by these devices can be displayed on the AIS page You can also see messages and position from SARTs and AtoNs within the defined range Pages YD42 Operation Manual 17 ...

Page 18: ...ivated it starts transmitting its position and identification data This data is received by your AIS device If your AIS receiver is not compliant with AIS SART it interprets the received AIS SART data as a signal from a standard AIS transmitter An icon is positioned on the AIS page but this icon is an AIS vessel icon If your AIS receiver is compliant with AIS SART the following takes place when AI...

Page 19: ...is defined as lost The target symbol represents the last valid position of the target before the reception of data was lost Selected AIS target activated by selecting a target symbol The target returns to the default target symbol when the cursor is removed from the symbol AIS SART AIS Search And Rescue Transmitter Page menu Range Defines the display range on the AIS page Selected range is indicat...

Page 20: ...wn on the AIS page You can select to hide safe AIS vessels and to not show targets based on vessel speed Target list The target list displays basic information for all received AIS targets For additional options Press the menu key Messages All received messages are listed in the Message listing To display a message Select the desired message and press the menu key Single time plot Page menu From t...

Page 21: ...Dual time plot Page menu From the page menu you can change the history time range and or shown data Pages YD42 Operation Manual 21 ...

Page 22: ...elected 3 Select the Calibrate option 4 Set the actual amount used based on amount of fuel added to the tank 5 Select OK to save settings The Fuel K Value should now show a new value Ú Note To calibrate multiple engines repeat the steps above one engine at a time Alternatively run all engines simultaneously and divide the Actual amount used by the number of engines This assumes reasonably even fue...

Page 23: ... to the correct value Adding fuel Enter the amount of fuel added to the tank or select the set to full option when filling the tank to its maximum capacity Fuel used The fuel used dialog shows the amount of fuel used since the last fill from trip reset and seasonal usage Fuel YD42 Operation Manual 23 ...

Page 24: ...ngines the fuel used data shown is the total for all engines It also lists data for each engine The reset option in the dialog allows resetting the fuel used data You can reset all engines or each engine separately 24 Fuel YD42 Operation Manual ...

Page 25: ...the siren the alarm message is followed by an audible alarm A single alarm is displayed with the name of the alarm as the title and details for the alarm If more than one alarm is activated simultaneously the alarm pop up can display 3 alarms The alarms are listed in the order they occur with the last activated alarm at the top The remaining alarms are available in the alarms dialog Engine alarms ...

Page 26: ... appear on the side of the display that the engine is configured Icon Alarm description Engine alarm Check active alarms DTCs for available information Low fuel level 25 The alarms dialog Active alarms Lists all active alarms 26 Alarms YD42 Operation Manual ...

Page 27: ...tores alarm messages until they are manually cleared To show alarm details or to clear all alarms Press the menu key and select the desired action Alarm settings To show the menu from where you can set the alarm limit and enable disable an alarm Press the menu key Alarms enabled Enables disables all alarms Alarms YD42 Operation Manual 27 ...

Page 28: ...Siren enabled Enables disables the alarm siren 28 Alarms YD42 Operation Manual ...

Page 29: ...e traveled through the water Log input To exit the trip log dialog Press the pages key To start stop or reset a trip Press the menu key and select the desired option Trip 2 Trip 2 records distance traveled over ground GPS input 5 Trip log YD42 Operation Manual 29 ...

Page 30: ...g Press the pages key To start stop or reset a trip Press the menu key and select the desired option Log The Log dialog shows total distance run from system installation or from a system restore 30 Trip log YD42 Operation Manual ...

Page 31: ...s Pre defined pages Template pages Motoring 000 0 Full screen Full screen Engine with static gauge Engine 2x1 Grid 2x1 Grid Engine with static gauge Fuel economy 2x2 Grid 2x2 Grid Engine with static gauge ft Depth history 2x2 Grid Offset 2x2 Grid Offset Engine with static gauge 6 User settings YD42 Operation Manual 31 ...

Page 32: ...ttom Basic Speed Depth 1 6 Digital bottom Basic Wind Angle Speed 1 3 Digital side GPS 1 4 Digital bottom Composite Wind Single analog AIS Analog 3 Single Time Plot Dual Time Plot Enable disable a page To make a page available for display it has to be enabled To enable disable a page Select the desired page and press the enter key 32 User settings YD42 Operation Manual ...

Page 33: ... press the menu key 2 Select the replace option and then select the preferred page Creating and editing a custom page A custom page is created in a two steps process 1 Replace one of the active pages with a template page refer to Replaceapage on page 33 2 Select the data to be shown in the page s data field s refer to Changingpagedata on page 12 User settings YD42 Operation Manual 33 ...

Page 34: ...ration option to correct any data inaccuracies from compatible NMEA 2000 devices For more information refer to the device documentation Ú Note Depending on the sensor some offsets calibrated here will only be applied locally Damping If data appears erratic or too sensitive damping may be applied to make the information appear more stable With damping set to off the data is presented in raw form wi...

Page 35: ... section Speed and course The extension line can be used to indicate speed and course for targets either as absolute true motion or relative to your vessel AIS icon orientation Sets the orientation of the AIS icon either based on heading or COG information MMSI Used for entering your own MMSI Maritime Mobile Service Identity number into the system You need to have this number entered to User setti...

Page 36: ...receive addressed messages from AIS and DSC vessels You also need to have your MMSI number entered to avoid seeing your own vessel as an AIS target 36 User settings YD42 Operation Manual ...

Page 37: ...nginesetup on page 42 Review the configurations made in the first time startup wizard Set the gauge limits to fit your equipment Accessing the system settings dialog The setup is done from the System settings dialog Network settings Sources Data sources provide live data to the system When a device is connected to more than one source providing the same data the user can choose the preferred sourc...

Page 38: ... is suitable for the majority of installations Manual source selection Manual selection is generally only required where there is more than one source for the same data and the automatically selected source is not the one desired Device list Selecting a device in this list will bring up additional details and options for the device All devices allow allocation of an instance number in the configur...

Page 39: ...e For device specific details refer to the device documentation Diagnostics Provides information useful for identifying an issue with the network NMEA 2000 Provides information on NMEA 2000 bus activity Ú Note The following information may not always indicate an issue that can be simply resolved with minor adjustment to network layout or connected devices and their activity on the network However ...

Page 40: ...ed Decimal places Defines number of decimals used for speed and sea temperature Key beeps Controls the loudness of the beep sound when a key is pressed Language Controls the language used on this unit for panels menus and dialogs Changing the language causes the unit to restart 40 Software setup YD42 Operation Manual ...

Page 41: ...e menu key Night mode Activates deactivates the night mode color palette Night mode color Sets the night mode color palette Invert day color Changes the background color for the pages from default black to white Sleep mode In Sleep mode the backlight for the screen and keys are turned off to save power The system continues to run in the background To exit Sleep mode Press the menu key Software set...

Page 42: ...before using it on the water When activated the simulator mode is indicated on the display Restore defaults Restores selected settings to default factory values Engine setup Vessel setup Set the number of engines fuel tanks and total fuel capacity Engine display setup A maximum of two engine s data can be shown on each gauge Engine model Select the engine model for the connected engine s Gauge lim...

Page 43: ...a pages They do not set any alarms Global reset Resets the source selection on all displays connected to the network About Displays copyright information software version and technical information for this unit Software setup YD42 Operation Manual 43 ...

Page 44: ... that are connected to the network from the unit Downloading the latest software The latest software is available for download in the product s section at www yanmarmarine com Update the unit s software 1 Download and save the latest software update file for the unit to a storage device 2 Make sure that the unit is turned off 3 Connect the storage device to the unit 8 44 Files YD42 Operation Manua...

Page 45: ...ion from the About dialog Remote device software update 1 Download and save the latest software update file for the remote device to a storage device 2 Connect the storage device to the unit 3 To start the update select the update file from the storage device The software version for connected NMEA 2000 sensors is available in the Device list Files YD42 Operation Manual 45 ...

Page 46: ... and select the desired backup file to start the import Warning Importing system settings overwrites all existing system settings Export system settings 1 Connect a storage device to the unit 2 Select the system settings option to initiate the export 46 Files YD42 Operation Manual ...

Page 47: ... dissolve and take away salt remains Crystallized salt sand dirt etc can scratch the protective coating if using a damp cloth Use a light fresh water spray then wipe the unit dry with a micro fiber or a soft cotton cloth Do not apply pressure with the cloth To clean the housing Use warm water with a dash of liquid dish soap or detergent Avoid using abrasive cleaning products or products containing...

Page 48: ...Dimensional drawings Min 70 0 mm 2 75 36 5 mm 1 43 118 0 mm 4 64 115 0 mm 4 53 28 5 mm 1 12 10 48 Dimensional drawings YD42 Operation Manual ...

Page 49: ...ption max 2 16 W 160 mA at 13 5 V DC Network load 1 LEN Display Size 4 1 diagonal 4 3 Aspect ratio Resolution 320 x 240 pixels Brightness 1200 nits Viewing angles 80 top bottom 80 left right Environmental Waterproof rating IPx7 Operating 25 to 65ºC 13 F to 149 ºF Storage 40 to 85ºC 40 F to 185 ºF 11 Technical specifications YD42 Operation Manual 49 ...

Page 50: ...te of Turn 127257 Attitude 127258 Magnetic Variation 127488 Engine Parameters Rapid Update 127489 Engine Parameters Dynamic 127493 Transmission Parameters Dynamic 127505 Fluid Level 127508 Battery Status 128259 Speed Water referenced 128267 Water Depth 128275 Distance Log 129025 Position Rapid Update 129026 COG SOG Rapid Update 129029 GNSS Position Data 129033 Time Date 129038 AIS Class A Position...

Page 51: ...afety Related Broadcast Message 129808 DSC Call Information 129809 AIS Class B CS Static Data Report Part A 129810 AIS Class B CS Static Data Report Part B 130074 Route and WP Service WP List WP Name Position 130306 Wind Data 130310 Environmental Parameters 130311 Environmental Parameters 130312 Temperature 130313 Humidity 130314 Actual Pressure 130316 Temperature Extended Range 130576 Small Craft...

Page 52: ...re 1 127489 110 65262 Engine Coolant Temperature 127489 167 65271 Alternator Potential Voltage 127489 183 65266 Engine Fuel Rate 127489 247 65253 Engine Total Hours of Operation 127489 109 65263 Engine Coolant Pressure 127489 94 65263 Engine Fuel Delivery Pressure 127489 92 61443 Engine Percent Load at Current Speed 127489 513 61444 Actual Engine Percent Torque 127489 189 65214 Engine Rated Speed ...

Page 53: ... Transmission Current Gear 127493 127 65272 Transmission Oil Pressure 127493 177 65272 Transmission Oil Temperature 127493 Ú Note The unit will act as a gateway and resend received J1939 PGN SPN over NMEA 2000 Supported data YD42 Operation Manual 53 ...

Page 54: ...54 Supported data YD42 Operation Manual ...

Page 55: ......

Page 56: ... 988 12234 002 YANMAR CO LTD https www yanmar com ...

Reviews: