8
In weighing mode, keep pressing [ Func ] for 5 seconds more, it will enter operator setting
mode (mode P), there are 12 modes from P1 to P12 for option, press [ * ] to choose the
mode and press [Tare] to change the parameter. The description of parameter as follows:
1
、
P1 x
kg Lb change
x=1:
kg display
x=2:
Lb display
2
、
P2 x
automatically power off
x=1:
No this function
x=2:
Power off 10 minutes later
x=3:
20 minutes
x=4:
30 minutes
3
、
P3 x
Baud rate setting
x=1:
9600
x=2:
4800
x=3:
2400
x=4:
1200
4
、
P4 x
RS232 Net/Gross weight output option
x=1:
Net weight output
x=2:
Gross weight output
x=3 Tare weight output
5
、
P5 x
RS232 output mode option
x=1:
No transmission (RS232 stop)
x=2:
Continuous transmission
x=3:
Continuous transmission when stable
x=4:
Command mode
(
Z
:
zero
,
T
:
tare
,
R
:
transmit weight data once time
)
x=5:
scoreboard display (Current loop output)
x=6:
scoreboard and RS232 simultaneously perform
6
、
P6 x Power saving function setting
x=1:
No power saving function
x=2:
With power saving function
x=3:
Invalid
7
、
P7 x
Zero-tracking scope
x=1:
0.5e
x=2:
1.0e
x=3:
1.5e
x=4:
2.0e
x=5:
2.5e