background image

 

15 

gross 

weight 

Indicator 

send  

Send gross 

weight  

02 AD 42 ** ** ** 

** ** ** ** ** XH 

XL 03 

02 41 42 2B 30 30 

30 2E 30 30 30 30 

36 03 

PC send 

To read net 

weight 

02 AD 43 XH XL 03 02 41 43 30 32 03

Indicator 

send 

Send net 

weight 

02 AD 43 ** ** ** 

** ** ** ** ** XH 

XL 03 

02 41 43 2B 30 30 

30 2E 30 30 30 30 

37 03 

PC send 

To read 

tare eight 

02 AD 44 XH XL 03 02 41 44 30 35 03

Indicator 

send 

Send tare 

weight 

02 AD 44 ** ** ** 

** ** ** ** ** XH 

XL 03 

02 41 44 2B 30 30 

30 2E 30 30 30 30 

30 03 

PC send  

To tare 

02 AD 45 XH XL 03 02 41 45 30 34 03

E  Indicator 

send  

Tare 

02 AD 45 XH XL 03 02 41 45 30 34 03

PC send 

To zero 

02 AD 46 XH XL 03 02 41 46 30 37 03

Indicator 

Zero 

02 AD 46 XH XL 03 02 41 46 30 37 03

PC send 

To start 

02 AD 47 XH XL 03 02 41 47 30 36 03 

G

Indicator 

send 

start 

02 AD 47 XH XL 03 02 41 47 30 36 03 

PC send 

To stop 

02 AD 48 XH XL 03 02 41 48 30 39 03 

H  Indicator 

send ` 

Stop 

02 AD 48 XH XL 03 02 41 48 30 39 03 

PC  send 

To  charge

02 AD 49    XH XL 03 02 41 49 30 38 03 

I

Indicator 

send  

Begin 

charge 

02 AD 49 XH XL 03 02 41 49 30 38 03 

PC send 

To 

discharge

02 AD 4A XH XL 03 02 41 4A 30 42 03 

J

Indicator 

send  

Begin 

discharge

02 AD 4A XH XL 03 02 41 4A 30 42 03 

PC send  

To 

Pause/Cont

inue 

02 AD 4B XH XL 03 02 41 4B 30 41 03 

K

Indicator 

send  

Pause/Cont

inue 

02 AD 4B XH XL 03 02 41 4B 30 41 03 

Summary of Contents for XK3190-C601

Page 1: ...XK3190 C601 WEIGHING INDICATOR BATCHING VERSION MANUAL PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE OPERATING Dec 2006 Specifications subject to change without prior notice ...

Page 2: ...n XK3190 C601 weighing indicator batching version adopts MCS 51 SCM and high speed Σ Δ A D conversion method with max 100 times s conversion speed It can make up batching scale with load cell and other mechanical parts applied in high speed and high precision weighing control occasion 1 2 Features Calibration and operation all by panel keys With parallel printing interface connected to stylus prin...

Page 3: ...ent 1 Turn scale off and cut off power before making any connections or disconnections Short connect PIN 1 AND PIN 2 PIN 6 and PIN 7 when connected to load cell with a 4 wire cable CAUTION Connection between load cell and indicator must be reliable shield wire must be connected to ground reliably Load cell and indicator are all static electricity sensitive devices measures must be taken to ensure ...

Page 4: ...en the frame indicator sends to PC is 0050 00 If the indicator displays 0 040KG then the frame indicator sends to PC is 000 040 B Command mode PIN ASSIGNMENT PIN ASSIGNMENT 1 RS422 OUTPUT 9 SCOREBOARD OUT 2 RS422 OUTPUT 10 SCOREBOARD OUT 3 RS422 IN 12 4 20mA I 4 RS422 IN 13 4 20mA I 6 RS232 RXD 14 CALIBRATION 7 RS232 TXD 15 CALIBRATION 8 GND Note1 RS422 output is optional Note2 Function of short c...

Page 5: ...m pc only triggers one operation hence several instructions should be sent from pc one by one to do these operations Instruction table is listed in appendix Connect indictor to scoreboard via 20mA current loop output Data is transmitted serially in binary code with baud rate 600 Data format is as listed below one group 0 1 2 3 4 5 6 7 8 9 10 START DATA Low is prior to high SIGN STOP Indicator send...

Page 6: ...he weight corresponding to 20mA 1 3 3 Connection with printer 25 pin interface Description for each pin is as listed in above table After connect to stylus printer indicator could print out weighing records accumulation value and formula 1 4 Layout at the back of various interfaces 2 TECHNICAL PARAMETERS AND SPECIFICATIONS Accuracy Class III N 3000 A D Conversion Method Σ Δ Input Signal Range 0mV ...

Page 7: ...utput touching capacity at AC 220V 0 5A Input Switch touching point close effective Operation Environment 0o 40o C Non condensed R H 90 Power Source AC220V 15 10 50HZ 2 2 3 LAYOUT AT FRONT AND DESCRIPTION Key board START key Press this key then indicator start working in automatic control status STOP key Press this key then indicator stop working in automatic control status ESC key Press this key ...

Page 8: ...DICATOR This is an input indicator It will be on when there is a short connect between pin 1 and pin 4 of control socket as listed in below table This input is usually given when weighing indicator works in manual control mode to start the charge control process I4 INDICATOR This is an input indicator It will be on when there is a short connect between pin 1 and pin 5 of control socket as listed i...

Page 9: ... will be on when weighing indicator is at the process of slow feeding for the first material O3 INDICATOR This is an output indicator It will be on when weighing indicator is at the process of fast feeding for the second material O4 INDICATOR This is an output indicator It will be on when weighing indicator is at the process of slow feeding for the second material O5 INDICATOR This is an output in...

Page 10: ...ge Stop Start Public I6 I5 I4 I3 I2 I1 When any of the pin from 2 to 7 is short connected to pin 1 it just gives indicator one kind of input corresponding input I indicator will be on Pin 8 to Pin 15 is for output description Pin 15 Pin 14 Pin 13 Pin 12 Pin 11 Pin 10 Pin 9 Pin 8 12V NOT OK OK Discharge Slow 2 Fast 2 Slow 1 Fast 1 O7 O6 O5 O4 O3 O2 O1 When indicator is at the process of one of the ...

Page 11: ...hese connection 6 Parameter A 0 outside code display 1 inner code display Parameter B 1 8 B 1 2 3 4 5 6 7 8 e 0 5 1 1 5 2 2 5 3 3 5 4 Parameter C D 0 5 C D 0 1 2 3 4 5 F S 0 2 4 10 20 100 Item Display Parameter description Remark 1 d Current date set Could set 2 t Current time set Could set 3 n Accumulation time Check only 4 A Accumulation value Check only 5 De1 0 Clear accumulation value or not4 ...

Page 12: ...rameter A is disabled If D of H is set as 1 then indicator will output 20mA analog signal when it reaches the value A set 3 FLt EF E AD parameter setting7 E AD sampling speed F AD filter intensity For example FLt 22 4 Adr Address for indicator8 1 26 5 bt Baud rate 0 4 0 600 1 1200 2 2400 3 48 00 4 9600 6 tod Communication mode 0 Continuously send 1 Command mode 7 Pt 8 PL Printing language 0 Englis...

Page 13: ...ameter set as 0 parameter t3 and t4 are disabled 14 Indicator will treat as discharge finish when tare weight is less than zero range Print and accumulation will only function when tare weight is more than zero range 15 Calibration head must be put on to save calibration data 2 Pt 0 Cycle times11 3 t0 12 Delay time before charge 4 t1 Delay time at fast feed finish 5 t2 Delay time at slow feed fini...

Page 14: ... zero indicator will be on 5 3 Tare At weighing status when the current display is positive and stable press TARE key will tare off the current weight and indicator will display 0 zero indicator is on 5 4 Date time set Press SET key and then press ENTER key and set date then press ENTER key and set time 5 5 Start Stop Item Display Parameter description Remark 1 dC Decimal point 0 3 Press ENTER aft...

Page 15: ...re is no required for charge material and indicator will begin charge automatically Always short connect pin 1 and pin 7 of control socket Indicator I6 will be always on if there is no required for discharge material only when O6 is on Then after o6 is on indicator will begin discharge automatically When indicator check that rest material in the hooper is within zero range it will begin the next c...

Page 16: ...41 45 30 34 03 PC send To zero 02 AD 46 XH XL 03 02 41 46 30 37 03 F Indicator Zero 02 AD 46 XH XL 03 02 41 46 30 37 03 PC send To start 02 AD 47 XH XL 03 02 41 47 30 36 03 G Indicator send start 02 AD 47 XH XL 03 02 41 47 30 36 03 PC send To stop 02 AD 48 XH XL 03 02 41 48 30 39 03 H Indicator send Stop 02 AD 48 XH XL 03 02 41 48 30 39 03 PC send To charge 02 AD 49 XH XL 03 02 41 49 30 38 03 I In...

Page 17: ... XH XL 03 02 41 4F 30 45 03 O Indicator send Print formula 02 AD 4F XH XL 03 02 41 4F 30 45 03 P PC send To print calibratio n rate 02 AD 50 XH XL 03 02 41 50 31 31 03 Indicator send Print calibratio n rate 02 AD 50 XH XL 03 02 41 50 31 31 03 PC send To read content of calibratio n rate Q Indicator send Send content of calibratio n rate 02 AD 51 NN XH XL 03 02 41 51 30 32 30 03 PC send To read par...

Page 18: ...NN C1 C2 C3 XH XL 03 02 41 55 30 32 35 35 31 36 03 PC send To clear accumulati on value 02 AD 56 XH XL 03 02 41 56 31 37 03 V Indicator send Clear accumulati on value 02 AD 56 XH XL 03 02 41 56 31 37 03 PC send To read date 02 AD 54 NN C1 C2 C3 XH XL 03 02 41 54 30 30 30 32 31 37 03 W Indicator send Send date 02 AD 54 NN C1 C2 C3 XH XL 03 02 41 54 30 30 30 32 31 37 03 PC send To read time 02 AD 58...

Page 19: ... C7 C8 XH XL 03 30 37 2D 32 36 31 45 03 PC send To write time 02 AD 5A C1 C2 C3 C4 C5 C6 C7 C8 XH XL 03 02 41 5A 30 39 3A 34 30 3A 32 36 31 32 03 Z Indicator send Write time 02 AD 5A C1 C2 C3 C4 C5 C6 C7 C8 XH XL 03 ...

Reviews: