X K 3 1 9 0
-
C 602
4
[******]
[A
A
]
Accumulated weight
A
—printing option
(0: no printing, 1:
printing
accumulative data, 2: printing all
data in memory)
The same as the above
Display of accumulative
weight: when the
effective value is
above 6 digits, the
digits of decimal will
automatically reduce.
When the integer is
above 6 digits, it can
only display 6 digits;
the number of left
decimal points which
are lit on represents
the number of digits
not displayed.
5
[
A
]
[dEL ]
Delete accumulative data and
weighing records
(0: no deleting; 1: deleting)
6
[
A
]
[Light ]
Brightness of display
(0-7)
Displayed content
A
—content in main display
A
0 1 2
Displayed
content
Weight
Internal
code
AD
code
B
—content in auxiliary display
B
0
1
2
3
4
5
7
[
AB
]
[dISP ]
Displayed
content
accum
ulated
times
accum
ulated
weight
Date Time
Worki
ng step
note1
Note
1
Note
2
Parameter
A
returns to
“0” upon each startup.
Display of accumulative
weight: when the
effective value is above
6 digits, the digits of
decimal will
automatically reduce.
When the integer is
above 6 digits, it can
only display 6 digits;
the number of left
decimal points which
are lit on represents the
number of digits not
displayed.
Note 1: it displays time in non-operation status.
Note 2: it displays batching value in operation status.