X K 3 1 9 0
-
C 602
is less than the batching value of material 1 minus tolerance of
material 1 and the gradual feed is allowed, go to program step 16
and the timer will be T3; If the gradual feed is not allowed and the
weight is more than the batching value plus tolerance,
out-of-tolerance treatment will stop at this step and wait for
qualified tolerance treatment. If the out-of-tolerance treatment is
not done, go to program step 18, the timer will be T5.
16
Start the slow feed of material 2, timing is over, the slow feed will
be closed and timer will be T4, go to program step 17.
17
Gradual feed. The disqualification treatment is as same as the
program step 6. If it is qualified, go to step 18.
18
Timing is over, close the qualified or out-of-tolerance signal. If
material feeding action is started manually, then stop the action; If
it is under the status of automatic cycle, then go to program step
19.
19
Perform the automatic print and automatic storage operation
according to the setting and go to the program step 20.
20
If there is an Add Signal, go to program step 21.
21
Material discharging. If the weight is back to Zero Zone, go to
program step 22 and the timer will be T6.
22
Timing is over and material discharging should be stopped. If the
material discharging is started manually, stop the action, otherwise,
go to program step 23.
23
Go to program step 24 and the timer will be T7.
24
Timing is over. If the cycle time set is not reached, stop the action.
Otherwise go to program step 1 to continue the cycle and the
surplus cycle time should be -1.
II. Subtracting scale